Strany 1 - Brushless Servo Drives

User’s GuideFor theMXBrushless Servo DrivesAmplifier ModelsMX-280, MX-440MX-850, MX-1300, MX-1600Motor ModelsBL-316, BL-340BL-455, BL-490, BL-4120BL-6

Strany 2 - User Manual

Soft startMax. inrush = 19.5A Resistor capacity: 33Ω 150 WBus Control (Shunt) ResistorsMX Series AmplifiersMX-280 MX-440 MX-850 MX-1300 MX-1600Resist

Strany 3 - CUSTOMER SERVICES

Refer to Section 6.3Pr41 RO Current Limit ValueRange 0 to +100 Resolution 1Displays the current limit value corresponding to whichever is the least of

Strany 4

Pr57 R/W At-Speed Window - upper limitRange +Full Scale Speed (Pr99) Resolution 1 rpmDefault 5 rpmSets the upper limit at which the At-Speed output wi

Strany 5

Default 3000 rpmSets the full scale value range for analog input and sets speed range for digital commands. +/- 10 volts onanalog speed command input

Strany 6 - Figure O.1

b06 R/W Command Selector - speed/current PDefault 00 Speed command, either analog or digital.1 Current command, either analog or digital.Warning:b06 m

Strany 7 - Input power supply voltage

b14R/WPulse / Direction mode PDefault 1 Firmware rev. 2.95 +b14 b17 mode0 0 Pulse / Direction mode1 0 Analog speed command modeX 1 I/O speed pres

Strany 8

0 without ramps1with rampsRefer to Section 4.2b33 RO Alarm Status0 at least one alarm is active1 no alarm activeSee Pr98, b03b38 RO Direction of Moto

Strany 9

1 Terminal modeRefer to Chapter 9.b53 R/W Orient Stop Mode Selector PDefault 00 stop and hold1 orient stop and holdSee Pr37, 27.b55 RO External Trip A

Strany 10

Defines the meaning of the signal given by the 'At-Speed' Status bit b42.1 (relative)The Actual motor speed is compared to the Speed Comman

Strany 11

Summary of Default Values — Numerical ParametersParameter Default Units NameP Pr00 0 rpm Digital speed preset 0P Pr01 0 rpm Digital speed preset 1P Pr

Strany 12

8.3.2 Summary of Defaults — Bit ParametersParameter Default Effect NameP b00 0 disable Security code change enableP b01 0 not Recall saved parametersb

Strany 13

Fast transient burst IEC 801 - 4 Level 3Resolver accuracy (arc min. total spread)Cable length PN 250224 ETWF Belden # 816410 ft 20 20 2050 ft 31 28

Strany 14

8.4.1 Alphabetical Index of Numerical ParametersAcceleration ramp forward Pr09Acceleration ramp reverse Pr10Alarm stored last Pr98Amplifier size code

Strany 15 - 2.3 Enclosures

8.4.1 Alphabetical Index of Numerical ParametersSpeed - full scale Pr99

Strany 16

8.4.2 Numerical Index of Numerical ParametersDigital speed preset 1 Pr00Digital speed preset 2 Pr01Digital speed preset 3 Pr02Digital speed preset 4

Strany 17

8.4.3 Alphabetical Index of Bit ParametersAlarm reset b03Alarm status b33At-speed indication type b96At-speed status b42Command selector speed/current

Strany 18 - Control Ground

8.4.3 Alphabetical Index of Bit ParametersSpeed loop saturation status b48Stop command bit b18Stop decel enable b22Stop input status b09Zero speed sta

Strany 19 - Enclosure Wiring

8.4.4 Numerical Index of Bit ParametersSecurity code change enable b00Recall saved parameters b01Drive enable bit b02Alarm reset b03Drive enable stat

Strany 20

8.4.5 COMBINED ALPHABETICAL INDEX OF NUMERICAL & BIT PARAMETERSAcceleration ramp forward Pr09Acceleration ramp reverse Pr10Alarm reset b03Alarm s

Strany 21

8.4.5 COMBINED ALPHABETICAL INDEX OF NUMERICAL & BIT PARAMETERSI/O digital input status Pr18I/O digital output selector 1 Pr30I/O digital output

Strany 22

9Serial CommunicationsThe serial interface allows direct connection between MX servo drives and a remote hostcomputer or programmable logic controller

Strany 23

Figure 9.2 shows the two serial protocol connections. An RS232 cable for connection to anIBM AT (9 pin) is available from Emerson EMC as Model number

Strany 24

Motor SpecificationsBLM/E-3XXX Torque Speed CurveFor mechanical dimensions see Appendix.BLM/E-4XXX Torque Speed CurveFor mechanical dimensions see App

Strany 25

Control CharactersTo conform to the standard structure of a message, the stages of a message are signalledby control characters. Each character has a

Strany 26

INTERROGATE THE DRIVE - 'Request Data'FormatThe query command consists of a maximum of 9 characters, but may use fewer. The formatmust be c

Strany 27

DRIVE REPLY TO INTERROGATION "Send data"The drive will reply with a message in the following format:| STX | Parameter | Data | ETX

Strany 28

Quick KeystrokesAfter the serial communication has been established to one axis by the first complete query,some data can be acquired with reduced tra

Strany 29

INSTRUCT THE DRIVE - 'Write Data'Data written to a drive controls its operation. A plc or a computer can therefore be incomplete and consta

Strany 30

TERMINAL MODETerminal mode uses a simplified protocol -| EOT | Address | CR |For example, for drive whose address is 02, if the axis selection s

Strany 31

Error MessagesPlain language error messages are returned in Terminal Mode as follows -SYNTAX ERRORMessage string does not comply with format.PARAMETER

Strany 32 - Control Terminals AZ8

SERIAL COMMUNICATIONSPARAMETERSP = Parameter protected by Security CodePr22 R/W Serial Address PRange 1 to 32 Resolution 1Default1Required for all sys

Strany 34

Logic Flow Diagram

Strany 35

2Installation — Mechanical2.1 Location and MountingIP RatingThe drive enclosure conforms to international enclosure specification IP20. This meansth

Strany 46

screws are provided, to ensure a good ground connection to the mounting surfacewhich should itself be bonded to ground.SpacingWhere two or more drives

Strany 53

12Quick StartThis chapter will show people who are experienced with servo drive systems how to getthe system started in a basic analog velocity comman

Strany 54

Suggested Ground bus bar dimensions:Lengthinches(mm)Widthinches(mm)Thicknessinches(mm)<20(500).75(20) .1875 to .2500(5.0 to 6.0)20 - 40(500 - 1000)

Strany 55

Figure 12.58 Grounding Schematic AZ16

Strany 56

In Figure 12.2 note the use of a separate isolated power system ground bus forconnecting the motor power wire shield and the amplifier ground terminal

Strany 57 - B5 CW limit switch

2.3 EnclosuresIf an enclosure is to be used, it is important to take into account the dimensions of theamplifiers to ensure adequate clearance for ai

Strany 58

Figure 12.3 shows the resolver cable interconnection between the MX amplifier and anEmerson EMC motor.Figure 12.60 Resolver Connections AZ19

Strany 59

Figure 12.4 shows how a motor with a brake should be connected. The system controllerwill have the ultimate decision on when to activate or deactivat

Strany 60

Figure 12.5 shows a quick overview of the control terminal connections of the MXamplifier. For details of their operation refer to Chapters 3 and 4.F

Strany 61

Figure 12.63 Encoder Simulation Connection AZ21

Strany 62

Encoder simulationVersion 2.96 and later have 4 resolution selections available and the selection is madevia Pr68. (The amplifier version is displaye

Strany 63

12.2 Preliminary SettingsPower up the system with the amplifier disabled (B14 disconnected) until the followingparameters are adjusted. NOTE: Rememb

Strany 64

Amplifier Current capacity chartCurrent rating (RMS amps)Amp ModelContinuous MaximumMX-280 2.8 5.6MX-440 4.4 8.8MX-850 8.5 17.0MX-1300 13.0 26.0MX-160

Strany 65

Figure 2.1 shows the mounting hole patterns andair flow requirements. For detailed dimensions,see Appendix.Figure 2.0 MX MountingDimensionsMXAMP

Strany 66

3Installation — Electrical3.1 General InformationSafetyThe voltages present in the supply cables, the output cables and terminals and incertain intern

Strany 67 - Power Supply Block Diagram

Table 3.A — Suggested Ground bus bar dimensions:Lengthinches(mm)Widthinches(mm)Thicknessinches(mm)<20(500).75(20) .1875 to .2500(5.0 to 6.0)20 - 40

Strany 68

Figure 3.1 Enclosure WiringAZ33

Strany 69

EMERSON EMC ♦♦♦♦ Subsid.: Emerson Electric Co.1365 Park Road ♦♦♦♦ Chanhassen, Minnesota 55317 ♦♦♦♦ 612/474-1116 Sales612/474-8833 Service (24 h

Strany 70 - Memory Diagram AZ2

Figure 3.1 shows pictorially how an enclosure should be wired for best groundingeffectiveness. Notice that the control ground and the high power grou

Strany 71

Figure 3.2 shows schematically how a system ground is wired for best grounding andcable shielding. Notice that the logic common on the MX amplifier i

Strany 72

3.2 EMI Interference3.2.1 IMMUNITYIf the instructions in this manual are observed, MX servo drives exhibit excellentimmunity to interference from exte

Strany 73

In the case of DC coils, a diode is installedacross the coil in a direction that will cause thevoltage transient to be shorted out through thediode.

Strany 74

In the installations that require EMI emissions to be significantly below the acceptableindustrial levels there are methods by which the EMI emissions

Strany 75

In figure 3.5 note the use of a separate isolated power system ground bus forconnecting the motor power wire shield and the amplifier ground terminal.

Strany 76 - Start-up Procedures

Figure 3.6 shows how additional suppression is accomplished by smoothing the PWMhigh frequency signals on the motor power cables and the incoming powe

Strany 77

Figure 3.7 shows a ferrite ring being used to reduce line disturbances if necessary inthe installation. The rings are installed by wrapping the bundl

Strany 78

3.3 Power ConnectionsPOWER WIRINGThe power terminals are located on the upper surface of the amplifier. (See FigureO.1.) The MX amplifier design all

Strany 79

3.3.1 FusingThe drive must be protected on the supply side either by dual element fuses (See thefuse ratings chart below) or by suitably-rated three-

Strany 80 - Figure 6.32

CUSTOMER SERVICESEmerson EMC offers a wide range of services to support our customer’sneeds. Listed below are some examples of these services.SERVICE

Strany 81 - = Pr99Then

3.4 Control Connections3.4.1 Control signal wiringThe terminals for the control circuits are on the front, protected by a removable cover(see Figure

Strany 82

and should not run parallel until they are separated by at least 10 to 12 inches.3.4.4 Serial linkFull duplex RS485 (RS 232 compatible) connection is

Strany 83 - Start Up Checkout AZ52

Figure 3.9 Control Terminals AZ8

Strany 84 - Figure 6.34

POWER TERMINALS3.5.1 Power Terminal Connector A (Models MX-280, MX-440)No Function Type DescriptionA1 Phase A outA2 Phase B out >Output to motorA3

Strany 85

3.5.2 Control Terminals "B" ConnectorNo Name & Function Type DescriptionB1 External trip/Limit Aux.Analog Inputin Auxiliary analog inpu

Strany 86

3.5.2 Control Terminals "B" ConnectorNo Name & Function Type Descriptionon b08B11 Zero volts3Control signals, analog and digital,common

Strany 87

3.5.2 Control Terminals "B" ConnectorNo Name & Function Type DescriptionB23 Sine high in Sine signal from resolverB24 Excitation low ou

Strany 88

3.5.3 Simulated Encoder Terminals CNo Function Type Description[Version 2.31 andearlier modelsonly. Pulse Modeselector.][Version 2.31 and earlier] -

Strany 89 - Figure 6.35

In Figure 3.10 note the use of a separate isolated power system ground bus for connectingthe motor power wire shield and the amplifier ground terminal

Strany 90

Figure 3.11 shows the amplifier modification required if an external shunt resistor is used. The external resistor is connected between terminals A9 a

Strany 91

0 INTRODUCTION AND CONTENTS 1 SPECIFICATIONS - AMPLIFIERS/MOTORS 2INSTALLATION - MECHANICAL 3 INSTALLATION - ELECTRICAL 4 FUNCTIONAL DESCRIPTIONS AN

Strany 92

modification has been made. This removes the risk that a modified drive might later beassumed to be in standard condition especially if it is removed

Strany 93

Figure 3.12 shows a quick overview of the control terminal connections of the MXamplifier. For details of signal operation see the individual connect

Strany 94

Figure 3.13 shows a pictorial connection diagram of the resolver interconnection betweenthe MX amplifier and an Emerson EMC motor.Figure 3.13 Resolver

Strany 95

Figure 3.14 Speed Command Input AZ26

Strany 96

Figures 3.15, 3.16, and 3.17 show the different ways of connecting to digital analog inputon Terminal B1. Terminal B1 has two different functions. I

Strany 97

Figure 3.16 Motor Thermal Sensor Connection AZ29

Strany 98

Figure 3.17 External Current Limit Connection AZ28

Strany 99

Figure 3.18 shows the digital outputs and how they are internally connected to source asignal when in an active state. Each output can drive up to 50

Strany 100

The Drive OK output is active when all the logic supplies are at the correct levels and thereare no Faults that shut down the amplifier output bridge.

Strany 101

Figure 3.20 shows how a motor with a brake should be connected. The system controllerwill have the ultimate decision on when to activate or deactivat

Strany 102

0IntroductionMX servo-drives are designed to operate in one of three command modes - speed, current, or pulse and directioncommand. For details on t

Strany 103

EncodersimulationVersion 2.96 andlater have 4resolutionselectionsavailable and theselection is madevia Pr68. Version 2.31 andearlier have tworesolutio

Strany 104

Figure 3.24 shows how the Pulse and Direction mode of control is connected. See section4.3 for details on implementation.Figure 3.24 Pulse-Direction

Strany 105

RS-485 and RS-232C ConnectionsRS-485 full duplex differential four-wire connection allows a multi-drop links to a maximumof 32 servo drives. The maxi

Strany 106

4Functional Descriptions and ConfigurationsIn reading this chapter it will be found helpful torefer to the Block diagrams in the Appendix.This section

Strany 107

continuous and Peak Current limit, I2t limit. These factors are used to set the amplifier todeliver peak performance with maximum safety. (See USER

Strany 108

• The status of the inputs at terminals B4 and B5 is displayed by Pr18.4.1.3 Acceleration and Deceleration FunctionTo enable, B07=1 To disable, b07=0

Strany 109

4.2 STOP FUNCTIONSThe Stop Function does two things: It stops the motor rotation with or without decel rampsand, it holds the motor position. This m

Strany 110

hard the motor will try to maintain the position. If the motor is forced out of position, itwill increase current to the motor and will continue incr

Strany 111 - Speed - full scale Pr99

stepper which can only assume that the motor actually moved. In performing the motion,the amplifier will provide all the power available to achieve t

Strany 112

digital.The analog current command mode is useful in applications where a servo-motor is to beoperated in a "torque helper" type of master/s

Strany 113

Figure O.1

Strany 114

4.5 Current (torque) Limit functionThe power stage of the drive is controlled by the current error signal at the summationpoint where the current fee

Strany 115

4.6 Most-used Configuration SettingsNote:The MX amplifier utilizes motor current phase advance above 3000 rpmwhich enables the motor to easily exceed

Strany 116

4.6.3 Accel/Decel RampingTo activate ramp function b07=1Rotation referenced when viewing the motor face.Table 4.F —Description Parameter Setting Defa

Strany 117

Figure 4.27 Feedback Resolution SelectionAZ14Version 2.31 and earlier, have two resolution selections available - 1024 lines perrevolution (4096 steps

Strany 118

4.8 Outputs4.8.1 Programmable Digital OutputsSelected by Pr30 - output at terminal B7Selected by Pr31 - output at terminal B8For both outputs, data i

Strany 119

4.9 Fault and Alarm HandlingTo the MX amplifier a fault is something that is an un-recoverable situation and in thesecases, the amplifier output is d

Strany 120

dangerous if the operator was investigating the reason for the machine stopping and themachine were to restart on it's own.ATTENTION!The amplifie

Strany 121

Figure 4.28 Power Supply Block Diagram

Strany 122

5Programming Keypad and MXP5.1 Keypad & DisplayThe keypad and display panel of MX servo drives is a demountable module whichincorporates the prog

Strany 123

DisplayA five-panel LED display window responds to the actions of the keys, displaying parameternumbers and values in accordance with a simple protoco

Strany 124

FEATURES OF THE MX SERVO DRIVE• MX amplifiers can be connected directly to three phase line power.• Customizing adjustments to control parameters can

Strany 125

Figure 5.30 Memory Diagram AZ2

Strany 126

5.2 Manipulation of ParametersFor details regarding parameter manipulation through the serial link please refer to Chapter 9after reading this sectio

Strany 127

The settings can be saved from the Working Table to the User Table (EEPROM) by settingb99=1. The contents of the Working Table are lost upon powering

Strany 128

Parameter display time-outIf, during parameter setting, no keystroke is made for approximately 8 seconds, the displayreverts either to rdY if the driv

Strany 129 - Logic Flow Diagram

5.3.1 To set a Security CodeAction EffectPress MODE The mode LED illuminates.The display shows the number of the last parameter tohave been accessed,

Strany 130

5.3.2 To change a Parameter Protected by the Security CodeAction EffectPress MODE The mode LED illuminates.The display shows the number of the last p

Strany 131

6Start-up ProceduresIn reading this chapter it will be found helpful to study andrefer to the Logic diagrams of the control system and theMode Selecto

Strany 132

6.3.1 Maximum CurrentA drive can deliver any level of current up to the maximum for which it is rated. Thismaximum is marked on MX nameplates as Imax

Strany 133

For example, if Imax is 8.8A and Ipk (the desired maximum current) is 5A, then -The resolutionof Pr42 is 1(%), so the value entered would be 57 in thi

Strany 134

Table 6.A — Standard system settings chartCurrent limitsMX Drive BL Motor Pr42 Pr45 Pr55MX-280 316-4 100 28 7340-4 100 44 7MX-440 455-4 100 36 8MX-850

Strany 135

Balanced 3Ø, 3-wire, 50 to 60 Hz Voltage range 380V -10% to 460V +10%Output VoltagesMotor Service voltage (380V to 460V) 3Ø less 10 VACDC bus voltage

Strany 136

6.4PID FunctionThe default values in the PID gains will need to be adjusted to the values that best match themotor and the load. The best starting va

Strany 137

Table 6.B — Standard system settings chartGain settingsMX Drive BL Motor Pr13 Pr14 Pr15MX-280 316-4 11 22 33340-4 14 25 28MX-440 455-4 14 30 30MX-850

Strany 138

values will be applied at the next power up.6.6 Resolver PhasingEmerson motors require a setting of Pr16 = 170.If a complete reset is performed on th

Strany 139

Figure 6.33 Start Up Checkout AZ52

Strany 140

Figure 6.34 Start Up Checkout (Cont'd) AZ52A

Strany 141

After the motion is completed, the display will show the phase difference between the motorand the resolver. Record the value displayed.Select Pr16 a

Strany 142

that b18=0 (default value).6.7.2Motor Function TestsFor the following tests it is recommended that the motor should be mechanically uncoupled,although

Strany 143

6.8.1Zero Speed Calibration (Offset)The applied speed command may sometimes have an offset, causing the motor to turnslowly with a zero command. Inpu

Strany 144

1 - Preliminary SettingsSet b07=0b12=1b18=0Pr58=maximum speed (=Pr99)Pr99=full-scale speed of the motor 1A - for Digital Command systemParameters

Strany 145

Speed may be reduced by decreasing the programmed values of Pr00, Pr01, Pr02,Pr03, or the inversion frequency may be increased by decreasing the value

Strany 146

each additional 100m (328 Ft.).Ventilation / CoolingMX servo amplifiers do not require external fans when mounted vertically as describedin the amplif

Strany 147

Figure 6.36 Overshoot Response AZ39Figure 6.37 Ideal Response AZ39BFigure 6.38 Overdamped Response AZ39A

Strany 148 - Grounding Schematic AZ16

6.8.3 - Tuning ProcedureEnable the drive by a 24V signal at terminal B14 and by setting b02=1. Wave forms such asthose shown in Figure 6.5 show a dyn

Strany 149

7Diagnostic ProceduresAll read-only (RO) parameters are software 'test points', enabling the user to monitor allsignificant functions of the

Strany 150 - Figure 12.60

shorts in motor leads, verify correct motor and power connections.Et10External trip. b55=1 — Usually motor overtemperature sensorconnection. Inhibit

Strany 151

has torque, develops peakcurrent, may vibrate, andenters I2t region.especially forswapped motorphases.With drive enabled and aspeed command applied,mo

Strany 152 - Figure 12.62

8Parameter DescriptionsProgrammable parameters are used in the MX amplifier to set up for the different modes of operation and to makevarious system a

Strany 153 - Figure 12.63

8.1 Numerical Parameters - DescriptionsPr00 R/W Digital Speed Preset 0 PRange -3000 to +3000 rpm if 200 ≤ Pr99 ≤ 3000-6000 to +6000 rpm if 3200 ≤ Pr99

Strany 154

Pr09 R/W Acceleration Ramp ForwardRange 1 to 3000 ms Resolution 1 msDefault 200 msThis is the slope of the ramp, measured in milliseconds per 1000 rpm

Strany 155

Pr18 RO I/O Digital Input Status (terminals B4 & B5)Range 0 to 3Signals at terminals B4 and B5 -- < 5V = 0> 5V = 1Configuration of Pr18 -Ter

Strany 156

Protects all R/W parameters marked P when Pr25 is set to any integer value >0. They can be read at anytime, but cannot be changed unless the secu