Type 630R Relief Valve
Introduction
The Type 630R is a general relief valve that is
available in NPS 1 and 2 / DN 25 and 50 body sizes.
It is frequently used at compressor stations, reneries 
and similar plants requiring a backpressure gas
regulator for relief pressure settings up to 250 psig /
17.2 bar.
Features
 —Provided by an O-ring seat.
 —The inlet adaptor acts as a
union nut enabling speedy inspection of trim parts.
 —The Type 630R is available in both
high-pressure and low pressure constructions; the
low pressure units have larger diaphragm area
to provide more accurate control of low pressure
settings while the high-pressure units can withstand
inlet pressure up to 550 psig / 37.9 bar and can
control pressures up to 250 psig / 17.2 bar.
 —The Type 630R relief valve
can be easily converted in the  eld to a Type 630 
regulator by reversing the actuator and using a new
valve carrier, disk, and ori ce. 
 —Optional materials
are available for applications handling sour
gases. These constructions comply with the
recommendations of NACE International Standards
MR0175 and MR0103.
Bulletin 71.4:630R
December 2011
D100158X012

Figure 1. Type 630R Relief Valve
W1934
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - Type 630R Relief Valve

Type 630R Relief ValveIntroductionThe Type 630R is a general relief valve that is available in NPS 1 and 2 / DN 25 and 50 body sizes. It is frequentl

Strany 2 - Bulletin 71.4:630R

Principle of OperationRefer to Figure 2. Inlet pressure registers beneath the diaphragm. As long as the inlet pressure is less than the set pressure

Strany 3

ADAPTORBODY

Strany 4

Optional materials are available for applications handling sour gases. These constructions comply with the recommendations o

Strany 5

Bulletin 71.4:630R5Table 3. NPT DimensionsFigure 3. NPT DimensionsLA B D F  L12 7.387.

Strany 6

16A7430BAFDBulletin 71.4:630R6LA B  D  FCL150 CL300 CL600 CL150 CL300

Strany 7

Bulletin 71.4:630R7* * * Readily Available for Shipment* * Allow Additional Time for Shipment*Special Order, Constructed f

Strany 8

Bulletin 71.4:630RThe Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owner

Komentáře k této Příručce

Žádné komentáře