www.Fisher.com
Fisherr C1 Pneumatic Controllers and
Transmitters
Fisher C1 controllers and transmitters continue the
tradition of durable and dependable Fisher pressure
instrumentation while addressing air/gas consumption
concerns. The C1 is used wherever durable and
dependable pressure instrumentation is required. The
use of this product in demanding applications, such as
those found in chemical process, gas, and oil
production industries, demonstrates its versatility. The
C1 can reduce steady-state air/gas consumption to as
little as 1/10th that of previous products.
C1 controllers compare sensed process pressure (or
differential pressure) with an operator-adjusted set
point, and send a pneumatic signal to an adjacent
control element that maintains the process pressure at
or near the set point value. C1 transmitters sense
process variables and send out a pneumatic signal,
usually to an indicating or recording device that
directly indicates the process measurement.
Unless otherwise noted, all NACE references are to
NACE MR0175 / ISO15156 & NACE MR0103.
Features
nWide Range of Sensing Elements—A Bourdon tube is
available for high pressures or bellows for vacuum
and low pressures. Either kind of sensing element
can be installed in the case with the controller or
transmitter. Two interchangeable ranges of output
bellows and gauges also are available.
nReduced Air/Gas Consumption—The C1 pneumatic
controller is an energy efficient choice, helping to
improve profits and uptime. Steady-state
consumption rate is less than the 6 scfh
requirement set for the oil and gas industry by the
US Environmental Protection Agency (New Source
Performance Standards Subpart OOOO,
EPA‐HQ‐QAR‐2010-0505).
FISHER C1 PNEUMATIC CONTROLLER
YOKE-MOUNTED ON CONTROL VALVE ACTUATOR
nSour Service Capability—Materials are available for
applications handling sour process fluids. These
constructions comply with the metallurgical
requirements of NACE MR0175 / ISO15156 & NACE
MR0103. Environmental restrictions may apply.
nMounting Versatility—Install the case on a panel,
wall or pipestand, as well as directly on the control
valve actuator.
nReduced Maintenance Costs—A spring-out cleaning
wire, shown in figure 4, provides for in-service
cleaning of the relay orifice.
nProportional-Only, Proportional-Plus-Reset, and
Differential Gap Configurable—The C1 controller
can be configured to provide various modes of
control.
(Features continued on page 3)
C1 Controllers and Transmitters
D103291X012
Product Bulletin
34.3:C1
July 2014
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Transmitters

www.Fisher.comFisherr C1 Pneumatic Controllers andTransmittersFisher C1 controllers and transmitters continue thetradition of durable and dependable F

Strany 2 - Specifications

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 10Figure 5. Bellows DetailsBELLOWS DETAILSSENSING BELLOWSBELLOWS SPRINGGE35

Strany 3 - Features (continued)

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 11Bourdon Tube ProtectionAll Bourdon tube constructions are available with

Strany 4

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 12Figure 8. Dimensions37.6(1.48)241.3(9.50)23.1(0.91)180.8(7.12)15.9(0.62)6

Strany 5 - Principle of Operation

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 2SpecificationsAvailable ConfigurationsSee table 1Input SignalPressureType:

Strany 6 - Proportional-Only Controllers

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 3Specifications (continued)Ambient Operating Temperature Limits(1)JStandard

Strany 7 - Differential Gap Controllers

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 4Table 2. Bourdon Tube Pressure Ranges and MaterialsPRESSURE RANGES(1)MAXIM

Strany 8 - Construction Features

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 5Table 5. Supply and Output Pressure Gauge RangesGauge Scale0.2 to 1.0 Bar

Strany 9 - Reverse/Direct Conversion

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 6Figure 1. Schematic of Reverse-Acting Proportional-Only and Proportional-P

Strany 10 - Pressure

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 7Figure 2. Schematic of Reverse-Acting Proportional-Plus-Reset Controller w

Strany 11 - Ordering Information

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 8Figure 3. Conversion from Reverse to Direct Action or Proportional to Diff

Strany 12 - Product Bulletin

C1 Controllers and TransmittersD103291X012Product Bulletin34.3:C1July 2014 9Figure 4. Fisher C1 ConstructionsPRESSURE BLOCKAND TUBINGRELAYORIFICESPRIN