CAUTION
Be careful when inserting the plug/stem assembly into the cage. Lower the plug into the cage slowly as this will seat the
seal ring to the plug. Make sure the seal ring (key 37) or backup ring (key 38) does not become disengaged from the cage
groove.
7. To insert the plug/stem assembly (key 3) into the cage (key 2), apply a general purpose silicone-based lubricant.
Slowly insert the plug/stem assembly into the cage.
CAUTION
If the packing is to be reused and was not removed from the bonnet, perform the following step carefully to avoid
damaging the packing with the stem threads.
8. Insert the bonnet and actuator yoke onto the valve body by completing the assembly according to steps 14 to 27 of
the section Replacing Packing, omitting step 17 if new packing is not being installed.
Parts Ordering
Eachvalveisassignedaserialnumberwhichcanbefoundonthevalveoronthenameplate(figure2andkey35,not
shown). The nameplate will normally be fitted to the actuator. Refer to this serial number when contacting your
Emerson Process Management sales office for technical assistance. When ordering replacement parts refer to this
serial number and give the part description from the following parts list.
WARNING
Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Process Management should
not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the
performance of the valve, and could cause personal injury and property damage.