Type MR105 Direct-Operated Pressure
Reducing Regulators
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,

causing property damage and personal
injury or death.
Fisher
®
regulators must be installed,
operated and maintained in
accordance with federal, state and
local codes, rules and regulations
and Emerson Process Management
Regulator Technologies, Inc.
(Emerson™) instructions.
If the regulator vents gas or a leak
develops in the system, service to the unit
may be required. Failure to correct trouble
could result in a hazardous condition.
Installation, operation and maintenance

personnel may result in improper
Figure 1. Type MR105 Direct-Operated Pressure
Reducing Regulators
adjustment and unsafe operation. Either
condition may result in equipment damage

personnel when installing, operating and
maintaining the Type MR105 regulator.
TYPE MR105 WITH
HIGH-PRESSURE ACTUATOR
TYPE MR105 WITH
LOW-PRESSURE ACTUATOR
Contents
Introduction .................................................................. 2
Specifications .............................................................. 2
Principle of Operation .................................................. 3
Installation ................................................................... 4
Overpressure Protection.............................................. 8
Startup ......................................................................... 8
Adjustment...................................................................9
Shutdown.....................................................................9
Maintenance .............................................................. 10
Parts List....................................................................16
P1204
P1205
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - Reducing Regulators

Type MR105D103246X012December 2014Instruction ManualForm 5874www.fisherregulators.comType MR105 Direct-Operated Pressure Reducing Regulators!WARNINGFa

Strany 2

Type MR10510and damage, make certain the drain valve (if used) is properly closed after 1. Isolate the regulator from the syst

Strany 3

Type MR10511Table 6. Type MR105 Product Assembly TorquePART NAME AND KEY NUMBERTORQUENPS  Body SizeNPS  Body SizeNPS  Body

Strany 4

Type MR105121. Remove the lower indicator tting (key 5) and attached parts. Proceed to step 5 if only maintenance on the indicator tting or attache

Strany 5

Type MR10513Actuator MaintenancePerform this procedure if it is desired to inspect or replace the diaphragm or other internal parts or if it is desire

Strany 6

Type MR10514alignment. Do not loosen the bonnet thread to align the pipe holes. Always tighten the bonnet to make alignment for the control line.NoteP

Strany 7

Type MR10515!WARNINGPersonal injury, equipment damage or 

Strany 8

Type MR1051616. Place the lower spring seat (key 54) and Belleville spring washer (key 49) over the actuator stem (key 40) and on top of the diaphrag

Strany 9

Type MR10517!WARNINGUse only genuine Fisher® replacement parts. Components that are not supplied by Emerson™ should not, under any circumstances, be u

Strany 10 - Type MR105

Type MR10518Key Description Part Number 9 Valve Spring, Inconel® X750 (NACE) NPS 1 / DN 25 10B1882X012 NPS 2 / DN 50 16A5499X012 NPS 3

Strany 11

Type MR10519Key Description Part Number 22 Flange Nut, Steel 14A5693X012 23 E-ring, Stainless Steel 14A8181X012 24 Drive Screw, Stainless St

Strany 12

Type MR1052The Specications section on this page provides the ratings and other specications for the Type MR105. The following informat

Strany 13

Type MR10520Key Description Part Number 52 Lower Spring Guide, Zinc-Plated Steel (NACE)(1) (Low-Pressure Actuator only) GE39171X012 53 Lowe

Strany 14

Type MR10521TYPE MR105 WITH LOW-PRESSURE ACTUATOR ASSEMBLYFigure 6. Type MR105 Direct-Operated Pressure Reducing Regulator Assemblies (continued)L1L16

Strany 15

Type MR1052254716463585657L1L1L1S515362L154716463585657L1L1L1S515362L1TYPE MR105 WITH HIGH-PRESSURE ACTUATOR ASSEMBLYFigure 6. Type MR105 Direct-Opera

Strany 16

Type MR10523Figure 6. Type MR105 Direct-Operated Pressure Reducing Regulator Assemblies (continued)DETAIL W36L1L172127L1L1NO TRAVEL INDICATOR1520216L1

Strany 17

Type MR105©Emerson Process Management Regulator Technologies, Inc., 2010, 2014; All Rights ReservedThe Emerson logo is a trademark and service mark of

Strany 18

Type MR1053Table 2. Outlet Pressure RangeActuator TypeSpring RangeSpring Part NumberSpring Color CodeSpring Wire D

Strany 19

Type MR1054Figure 2. Type MR105 with Low-Pressure Actuator Operational SchematicM1178CONTROL SPRINGACTUATORACTUATOR STEMCAGEVALVE SPRINGVALVE PLUGDIAP

Strany 20

Type MR1055Figure 3. Type MR105 with High-Pressure Actuator Operational SchematicM1181SPRING

Strany 21

Type MR1056NoteTo avoid premature wear of internal parts, it is recommended that the actuator be oriented up or down in liquid 

Strany 22

Type MR1057Table 5. Wide-Open Flow and IEC Sizing CoefcientLINEAR CAGEBody Size Line Size Equals Body S

Strany 23

Type MR1058!WARNINGPersonal injury, equipment damage or if the bonnet (key 61, Low-Pressure Actuator) or lower

Strany 24

Type MR10591. Check that proper installation is completed and downstream equipment has been properly adjusted.2. Make sure all block and vent valves