14 Sensor Installation: F-Series
Mounting the Sensor
Mounting the electronics of high-temperature and extreme high-temperature sensors
High-temperature and extreme high-temperature F-Series sensors come with a 32 (812 mm) pre-installed
flexible conduit. This conduit is required for agency approval.
A factory-supplied Model 1700/2700 transmitter, core processor, or junction box is connected to the end of
the flexible conduit. Mount the electronics to a wall or instrument pole using the supplied bracket (Figure 10).
Figure 10 Electronics mounting for high-temperature F-Series sensors
Mounting
bracket
(wall mount)
Use 4 × 5/16 (8 mm)
bolts to secure the
bracket to a wall
Slide the electronics into the
bracket groove.
Mounting
bracket
(instrument pole)
Use 2 × 5/16 (8 mm)
U-bolts to secure the
bracket to an
instrument pole
Secure the electronics to the
bracket with the 4 #10 screws.