Emerson ZX Platform Condensing Unit Manuál

Procházejte online nebo si stáhněte Manuál pro Split-systém klimatizace Emerson ZX Platform Condensing Unit. Emerson ZX Platform Condensing Unit Product manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
EMERSON
ZX Platform Condensing Unit
PRODUCT MANUAL
Leading the Future in Refrigeration Technology
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - PRODUCT MANUAL

EMERSONZX Platform Condensing UnitPRODUCT MANUALLeading the Future in Refrigeration Technology

Strany 2

E2 Power Board E2 Control BoardFigure 09E2 Display DiagnosticRemote BuzzerWith VolumeFigure 108Figure 09 shows the ZX platform E2 controller and figur

Strany 3

The E2 controller consists of 2 electronic board assemblies: E2 power board and control board. The power board supplies constant DC power to the E2 c

Strany 4 - ZX – design platform

10ZX platform- technical specificationsNomenclature Electrical Codes Code 50HZ D 380V/420V-3 Compressor Motor Code Description T Three

Strany 5

Envelope11Emerson ZX Platform Condensing Unit PRODUCT MANUALRefrigerant –R404A, R22Maximum Suction Gas Temperature: 200CAmbient Temperature0C 1048-4

Strany 6 - ZX Low Temperature CDU

12Performance TablesZX MT Unit Capacity And Power (kW) At 50Hz For Refrigerant R22ZX0200ZX0300ZX0400ZX0500ZX0600ZX0750ZX076027323843482732384348273238

Strany 7

Performance TablesZX MT Unit Capacity And Power (kW) At 50Hz For Refrigerant R404a13Emerson ZX Platform Condensing Unit PRODUCT MANUAL273238432732384

Strany 8

14Performance TablesZX LT Unit Capacity And Power (kW) At 50Hz For Refrigerant R22ModelAmbientTemp eratu re(oC)Evaporating Temperature (oC)CapacityEva

Strany 9

Performance TablesZX LT Unit Capacity And Power (kW) At 50Hz For Refrigerant R404a15Emerson ZX Platform Condensing Unit PRODUCT MANUALModelAmbientTem

Strany 10

16ZX LT Unit (Liquid Line Temperature)Typical Liquid Line TemperatureoC 481416192326304311131619222529333738791214182125293332791214182125293327-3-125

Strany 11 - PRODUCT MANUAL

Wiring Diagram (ZX MT & LT Units)17Emerson ZX Platform Condensing Unit PRODUCT MANUAL

Strany 12 - Bill Of Material (BOM)

The Emerson ZX platform condensing unitZX – reliability platformZX – performance platformZX – design platformEmerson ZX platform – scroll superiorityP

Strany 13 - Envelope

18Technical Data ZX MT UnitsZX0200ZX020E3.85/4.302.41/2.26ZX15KC-TFDZX15KCE-TFD2MINERAL/POE1.18 0.54.3/5.02611164508305.1/4.43/41/26076 1029X424X84029

Strany 14 - Performance Tables

19Emerson ZX Platform Condensing Unit PRODUCT MANUALZXL0200ZXL020E1.7/2.111.20/1.242.37/2.861.51/1.51ZXI06KC-TFDZXI06KCE-TFD2MINERAL/POE0.56 0.55.4/5

Strany 15

20Dimensional Drawing (ZX MT & LT Units) ALL MODELSY110X2 HOLES 15MM DIA2-R7.5MM GROOVEHeba707023WZX0200/E, 0300/E, 0400/EZXL0200/E, 0250/E, 0300/

Strany 16

21Emerson ZX Platform Condensing Unit PRODUCT MANUALDiagnostic Messaging – LED Definitions (ZX MT and LT Units)Idle (Stop When Reach To Set-point)Run

Strany 17

22Diagnostic Initialization Message (ZX MT and LT Units)When the unit is initially powered on, the diagnostic module will show the following signal.(1

Strany 18

23Emerson ZX Platform Condensing Unit PRODUCT MANUALZX MT Units (Dip Switch And Rotary Switch Settings)Spare Board ZXI06KC/E-TFD ZXI08KC/E-TFD ZXI09K

Strany 19

24E2 controller trip set-points & actions (ZX MT & LT units)Fault TypeReverse Phase / Loss Of Phase (3 Phase Only)Fresh Start High Pressure Tr

Strany 20 - Technical Data

25Emerson ZX Platform Condensing Unit PRODUCT MANUALFault TypeDischarge Line And Coil In Temperat ure Sensors FailureAmbient Temperat ureSensor Failu

Strany 21

Contact us at:[email protected] 2009Emerson Climate Technologies,Asia Pacific Headquarters10/F, Pioneer Building,,213 Wai Yip Stre

Strany 22 - ALL MODELS

The Emerson ZX platform condensing unitsEmerson Climate Technologies is pleased to offer the ZX platform refrigeration condensing units (CDU) specific

Strany 23

2ZX – reliability platform Emerson Climate Technologies has designed the ZX platform CDUs with extended operational capability in tough climatic condi

Strany 24

Emerson ZX platform – scroll superiorityScroll compressors deliver flatter capacity compared to reciprocating compressor condensing units due to the h

Strany 25

4Physical layout of the ZX platform CDUThe unique features of Emerson’s ZX platform CDU as described above are quite different from the conventional C

Strany 26

In ZX MT units, suction line injection is applied to the compressor suction. Suction line injection allows a reliable and efficient MT envelope of up

Strany 27 - ZX LT CDU

6Figure 07 identifies the key components layout of the E2 Control and Electrical components layoutFigure 08 identifies other major refrigerant compone

Strany 28 - Jan 2009

ZX Platform E2 control featuresZX platform E2 control offers multiple features which are unique to refrigeration condensing units. E2 real-time contro

Komentáře k této Příručce

Žádné komentáře