Emerson ACE95Jr Datový list Strana 3

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 2
Bulletin 74.1:ACE95JR
3
When the actuator moves downward, it pushes open the
valve plug which allows ow in to the tank. See Figure 2.
When pressure in the tank increases above setpoint, the
large actuator diaphragm is pushed upward, allowing the
valve plug to close.
The valve plug is balanced (inlet pressure creates equal
upward and downward force on these components);
therefore, the outlet (control) pressure of the unit is not
affected by uctuating inlet pressure.
Installation
The Type ACE95jr tank blanketing valve was assembled
and preset to the customer specied pressure and
setpoint at the factory. The outlet (control) pressure range
of the valve is stamped on the nameplate fastened to the
upper actuator case. The gas blanketing setpoint is the
only adjustable feature on this unit.
INLET PRESSURE
TANK PRESSURE
ATMOSPHERIC PRESSURE
VALVE OPEN
VALVE CLOSED
SENSING
CONECTION
ROLLING
DIAPHRAGM
O-RING SEAT
CAGE
POPPET
INLET
TO TANK
Figure 2. Operational Schematic
E0205
Outlet Check Valve—Prevents corrosive gases and
vapors from owing back into the blanketing system
through the delivery line.
Single Array Manifold (SAM)—Provides sense line
connection and main valve connection through a single
tank nozzle.
Inlet Filter—Screens out any foreign material upstream
that may cause blockage in the gas ow.
Principle of Operation
The Type ACE95jr tank blanketing valve controls the
vapor space pressure over a stored liquid. When liquid is
pumped out of the tank or vapors in the tank condense, the
pressure in the tank decreases. Tank pressure is sensed
by the large actuator diaphragm. When tank pressure is
less than the valve set pressure, spring force moves the
actuator diaphragm downward.
Zobrazit stránku 2
1 2 3 4 5 6 7 8

Komentáře k této Příručce

Žádné komentáře