Bulletin 71.1:CSB400
8
TYPE CSB403 TRUE-MONITOR BACKUP ORIFICE DEVICE
Damage/nick on seat X X
Damage to disk X X
Damage or disconnected lever X - - - -
Damage to diaphragm X - - - -
Blocked or broken registration to primary regulator X - - - -
1. AstheIntegralMonitorisexternallyregistered,itisrequiredthatthePrimaryandIntegralWide-OpenMonitordonotsharedownstreamsenselines.
Table 6. True-Monitor Protection vs. Backup Orice Device
Integral True-Monitor™ Protection
TypesCSB403andCSB423combinetheoperationof
aconventionaltwo-regulatorwide-openmonitorsetinto
onebody.TheIntegralTrue-Monitorinstalledontheinlet
sideofthebodyandservestothrottleowandmaintain
anacceptabledownstreampressureinthecasewhere
thePrimaryregulatorceasestocontrolthedownstream
pressure.Unlikemultipleseatdesignsthatrelyonthe
primaryregulatorforallfailuremodes,theTypeCSB403
providesprotectionfromawidevarietyofoccurrences
thatcouldcausethePrimaryregulatornottoregulate
downstreampressure.Table 6 showsacomparison
betweentheIntegralTrue-Monitorprotectionandthe
protectionofferedbyanoricebackupdevice.
RefertoFigure5.IfthePrimaryregulatorceasesto
controldownstreampressure,outletpressurewillrise
underneaththediaphragmoftheIntegralmonitor,which
willassumecontrolofthedownstreampressure.
Table6showsacomparisonbetweentheIntegral
True-Monitorprotectionandtheprotectionofferedby
Figure 5. Type CSB403IT Internally Registered Primary Regulator with Externally Registered Integral Monitor Operational Schematic
Type CSB403IT Regulator with Token Relief and Monitor
MXXXX
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
May 2008
Type CSB403
TANK PRESSURE
VACUUM PRESSURE
PRE-EXPANSION PRESSURE
INTERMEDIATE BLEED PRESSURE
PILOT SUPPLY PRESSURE
INTERMEDIATE PRESSURE
LOADING PRESSURE
PUMP PRESSURE
BYPASS PRESSURE
BACK PRESSURE
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
VACUUM PRESSURE
PRE-EXPANSION PRESSURE
INTERMEDIATE BLEED PRESSURE
PILOT SUPPLY PRESSURE
INTERMEDIATE PRESSURE
PILOT SUPPLY PRESSURE
VACUUM PRESSURE
TANK PRESSURE
VAPOR PRESSURE
LOADING PRESSURE
BYPASS PRESSURE
BACK PRESSURE
PUMP PRESSURE
BOOST PRESSURE
EXHAUST
PILOT LOADING PRESSURE
VENT HEADER PRESSURE
INLET BLEED PRESSURE
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
M1098
EXTERNAL CONTROL
LINE (SENSE LINE)
PRESSURE RETAINING
PLUG (DO NOT
REMOVE WHILE UNIT
IS PRESSURIZED)
MONITOR ADJUSTING SCREW
REGULATOR ORIFICE
REGULATOR
ADJUSTING SCREW
REGULATOR
CONTROL SPRING
MONITOR CONTROL SPRING
MONITOR DISK
MONITOR
LEVER
MONITOR
VALVE STEM
MONITOR
OPENING SPRING
BALANCED PORT
ASSEMBLY
REGULATOR
VALVE STEM
REGULATOR
LEVER
REGULATOR
PUSHER POST
WIDE-OPEN INTEGRAL MONITOR REGULATOR PRIMARY REGULATOR
TOKEN RELIEF
SPRING
MONITOR ORIFICE
downstreamsystemviaaslam-shutthatactivatesif
thedownstreamsystempressurerisesaboveorfalls
belowthesetpointoftheslam-shut.
Upstream Monitoring Regulator
TypesCSB410,CSB414,CSB430andCSB434
actasseparateupstreammonitoringregulators.
Theseupstreammonitorregulatorsactinthesame
mannerasaTypeCSB400withexternalpressure
registrationonly,theyareinstalledupstreamofa
primaryregulator.IfthedownstreamPrimaryregulator
ceasestocontrolthedownstreamsystempressure
anddownstreampressurebeginstoincrease,this
pressure increase is registered underneath the
diaphragmoftheUpstreamMonitorregulatorthrough
thedownstreamcontrolline.Theincreasedpressure
willovercometheforceforthecontrolspringand
causethediaphragmassemblytomoveupward,
therebymovingtheleverupwardandmovingthedisk
closertotheoricetoregulateowanddownstream
systempressure.