Table 1. Main Valve Body Sizes, End Connection Styles and Body Ratings
MAIN VALVE BODY SIZE
MAIN VALVE BODY MATERIAL END CONNECTION STYLE
STRUCTURAL DESIGN RATING
NPS DN psig bar
1 25
LCC or WCC Steel
NPT or SWE 1500 103
CL150 RF 290 20.0
CL300 RF 750 51.7
CL600 RF or BWE 1500 103
2 50
NPT or SWE 1500 103
CL150 RF 290 20.0
CL300 RF 750 51.7
CL600 RF or BWE 1500 103
3 80
CL150 RF 290 20.0
CL300 RF 750 51.7
CL600 RF or BWE 1500 103
4 100
CL150 RF 290 20.0
CL300 RF 750 51.7
CL600 RF or BWE 1500 103
Table 2. Outlet Pressure Ranges
TYPE
OUTLET PRESSURE
RANGE
AC (ACCURACY CLASS) PILOT CONTROL SPRING INFORMATION
psig bar Type EZH Type EZHSO Spring Color Part Number
PRX/120
PRX/125
14.5 to 26
23 to 44
41 to 80
73 to 123
1.00 to 1.8
1.6 to 3.0
2.8 to 5.5
5.0 to 8.5
2.5%
2.5%
2.5%
2.5%
2.5%
2.5%
2.5%
2.5%
Yellow
Green
Blue
Black
M0255240X12
M0255230X12
M0255180X12
M0255220X12
116 to 210
203 to 334
319 to 435
8.0 to 14.5
14.0 to 23.0
22.0 to 30.0
1%
1%
1%
2.5%
2.5%
2.5%
Silver
Gold
Aluminum
M0255210X12
M0255200X12
M0255860X12
PRX/120-AP
PRX/125-AP
435 to 1160 30.0 to 80.0 1% 2.5% Clear M0273790X12
Table 3. Minimum Differential Pressures
(1)
TYPE
MAIN VALVE BODY SIZE MINIMUM DIFFERENTIAL
NPS DN
For 90% Capacity For 100% Capacity
psid bar d psid bar d
EZH
1 25 15.2 1.1 15.7 1.1
2 50 12.0 0.83 13.8 0.95
3 80 10.6 0.73 12.8 0.88
4 100 15.8 1.1 16.4 1.1
EZHSO
1 25 55 3.8 55 3.8
2 50 55 3.8 55 3.8
3 80 55 3.8 55 3.8
4 100 55 3.8 55 3.8
1. When using a Type SA/2 pilot supply lter regulator, the differential pressure across the regulator must be a least 45 psid / 3.1 bar d for optimum regulator performance.