FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
164
7.3.6.2 IPMB Link Sensor
The following table describes the IPMB link sensor on the PEMs.
Hysteresis support
Threshold access support
Event Message Control Entire Sensor Only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
Reading Type According to PICMG 3.0
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x84, 0x77, 0x71 (42.24, 38.08, 36.16) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xE1, 0xEB, 0xEE (72, 75.20, 76.16) Volts
Table 7-49 Sensor No. 0, Hot Swap (continued)
Feature Raw Value/Description Interpreted Value
Table 7-50 Sensor No. 1, IPMB Physical
Feature Raw Value/Description Interpreted Value
Sensor Name IPMB Physical
Type of Measurement IPMB Link State
Class 0x6F Discrete
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0xF1 IPMB Link
Sensor Owner LUN 0x00
Entity ID 0x0A
Entity Instance 0x60
Rearm Mode Auto
Hysteresis support
Zobrazit stránku 163