Product Data Sheet
00813-0100-4811, Rev DA
Catalog 2008 - 2009
Rosemount 3300 Series
Level-6
Select Guided Wave Radar Transmitter
A Rosemount 3300 Series transmitter consists of a
transmitter housing, a tank connection and a probe.
Probe and tank connection are the only parts in
contact with the tank atmosphere.
The transmitter can be equipped with different
probes to fulfill various application requirements.
TRANSMITTER HOUSING
The transmitter is available in two models (see page
Level-2 and 5), 3301 and 3302 and it can be ordered
with Intrinsically Safe or Explosion Proof / Flame
Proof certification (see “Product Certifications” on
page 17). The housing is available in polyurethane
covered Aluminium or Stainless Steel.
The dual compartment transmitter housing can be
removed without opening the tank. It has electronics
and cabling separated. The housing has two entries
for conduit/cable connections.
The 3300 Series is available with a 1/2 in. NPT cable
entry, or an M20 adapter as an option.
See “Ordering Information” on page 28.
TANK CONNECTION
The tank connection consists of a tank seal, a
flange
(1)
or NPT or BSP/G threads
(2)
. See “Ordering
Information” on page 28).
Flange mating face dimensions follow ANSI B 16.5,
JIS B2220, and EN 1092-1 (DIN 2527) standards for
blind flanges.
Fisher and Masoneilan flanges are also available
(see “Special Flanges and Flushing Connection
Rings” on page 27).
Flanged Hastelloy
®
, Monel
®
and PTFE covered
probes have a tank connection design with a
protective plate made of the same material as the
probe, to prevent the 316L / EN 1.4404 SST flange
from being exposed to the tank atmosphere.
Process Temperature and Pressure
Ratings
The following diagrams give process temperature
(maximum product temperature at the lower part of
the flange) and pressure ratings for tank connection
types:
Standard (Std)
High Pressure (HP)
High Temperature and High Pressure (HTHP)
For the standard tank connection, the final rating
depends on flange and O-ring selection (see table on
page Level-7).
(1) EN (DIN), ANSI, Fisher or Masoneilan, see pages 27-28
(2) 1 or 1.5 in. depending on probe type
1
Tank
Connection
Probe
Dual
Compartment
Transmitter
Housing
2
3
1
2
Tank Seal with Plate Design
Protective plate
Pressure
psig (bar)
Temperature
°F (°C)
PTFE covered
probe and flange
(model code 7)
Max. Rating, Standard Tank Connections
580 (40)
232 (16)
-14 (-1)
-40 (-40)
302 (150)