Ordering Information
MODEL CODE 5301 AND 5302 LEVEL AND/OR INTERFACE IN LIQUIDS
Model Product Description
5301 Guided Wave Radar Liquid Level or Interface Transmitter (interface available for fully submerged probe)
5302 Guided Wave Radar Liquid Level and Interface Transmitter
Code Signal Output
H 4-20 mA with HART
®
communication
FF
OUNDATION™ fieldbus
Code Housing Material
A Polyurethane-covered Aluminum
Code Conduit / Cable Threads
1 ½ - 14 NPT
2 M20 x 1.5 adapter
E M12, 4-pin, Male connector (eurofast
®
)
(1)
M A size Mini, 4-pin, Male connector (minifast
®
)
(1)
Code Operating Temperature and Pressure
(2)
Probe Type
S - 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C) All
H High Temp / High Pressure
(3)
:
2940 psi @ 752 °F and 5000 psi @ 100 °F (203 bar @ 400 °C and
345 bar @ 38 °C) according to ANSI Class 2500
3A, 3B, 4A, 5A and 5B (only SST)
P High Pressure
(3)
:
Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar
@ 200 °C and 345 bar @ 38 °C) according to ANSI Class 2500
3A, 3B, 4A, 5A and 5B (only SST)
Code Material of Construction
(4)
: Process Connection / Probe Probe Type
1 316 / 316 L SST (EN 1.4404) All
2Hastelloy
®
C-276 (UNS N10276). With plate design if flanged version. 3A, 3B, 4A
3 Monel
®
400 (UNS N04400). With plate design if flanged version. 3A, 3B, 4A
7 PTFE covered probe and flange. With plate design. 4A and 5A
8 PTFE covered probe 4A and 5A
Code Sealing, O-ring Material (Consult factory for other o-ring materials)
N None
(5)
VViton
®
fluoroelastomer
E Ethylene Propylene
K Kalrez
®
6375 perfluoroelastomer
B Buna-N
Code Probe Type Process Connection Probe Lengths
1A Rigid Twin Lead
(7)
Flange or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
2A Flexible Twin Lead with weight
(7)
Flange or 1.5 in. Thread Min: 3 ft 4 in. (1 m). Max: 164 ft (50 m)
3A Coaxial (for level measurement)
(6)
Flange, 1
(7)
or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)
3B Coaxial, perforated. For level and interface
measurement, or easier cleaning.
Flange, 1
(7)
or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)
4A Rigid Single Lead Flange, 1
(7)
or 1.5 in. Thread Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
5A Flexible Single Lead with weight Flange, 1
(7)
or 1.5 in. Thread Min: 3 ft 4 in. (1 m). Max: 164 ft (50 m)
5B Flexible Single Lead with chuck
(8)
Flange, 1
(7)
or 1.5 in. Thread Min: 3 ft 4 in. (1 m). Max: 164 ft (50 m)
Code Probe Length Units
E English (feet, in.)
M Metric (meters, centimeters)
Komentáře k této Příručce