13
“H” High DC Bus
This fault is indicated by the display showing a “H”. The DC bus is internal to the drive.
This indicates a fault involving the DC bus and voltages or with its associated
components.
Potential causes for the “H” High DC Bus fault
• DC Bus exceeds 440 VDC (EN), 415 VDC (Epsilon)
• Open Shunt Resistor either internal or external
• RSR-2 module malfunction or improper installation
• High AC input line
• High inertial load, deceleration ramps too aggressive
“H” “High DC Bus Fault”
EN-208
And EN-214
Drives
High AC
Input line
Reset
with Reset P/B
Yes
> 264 VAC
Investigate Cause
for Increase
High Inertia Load/
Decel Ramps
Overly Agressive
Monitor
AC Input
>264 VAC 47-63 Hz
No
Yes
Yes
No
"H" Fault
High DC Bus
"H" Fault
High DC Bus
"H" Fault
High DC Bus
Returns
to
Normal Operation
No
Examine Program
Modify Motion
AT/DT/VEL
as required
System Uses RSR-2 Module
and ES Unit
External Shunt Resistor
Yes
Use RSR-2
Troubleshooting
Procedure
EN-204
All Epsilon
Drives
Return
to Factory
Open Internal
Shunt Resistor/Shunt Fuse
*
*
Shunt Fuse or Resistor cannot
be checked in field.
Yes
No
Potential Misapplication
or External Resistor
RSR and ES Maybe Needed
Contact Tech Support
Investigate
High Inertia
Return
to Factory
End
Returns
to
Normal Operation
Return
to Factory
End
No
Komentáře k této Příručce