d. Tighten the screw or nut to the torque specified in table 3.
12. Insert the piston and piston rod assembly down through the sliding seal (key 19). Attach the hex nut (key 71),
turnbuckle (key 70), hex nut (key 11), and r od end bearing (key 12) to the piston rod assembly.
13. Rotate the lever to align with the rod end bearing. This connection can be aided by carefully moving the piston/rod
assembly up or down.
14. Apply thread locking adhesive (medium strength) (key 92) or equivalent thread-locking compound to the threads
of the cap screw (key 13).
15. Connecting the lever to the rod:
D For Size 30, 40, 60, and 68 actuators: Connect the lever and the rod end bearing with the cap s crew and hex nut (keys
13 and 14).
D For Size 80, 100, and 130 actuators: Connect the lever and the rod end bearing with the cap screw, washer, and hex
nut (keys 13, 84, and 85). Size 130 does not require the washer (key 84).
16. I nstall the O-ring (key 8 or 16) on the piston edge. Apply lithium grease lubricant (key 93) to the inside wall of the
cylinder. Install the cylinder (key 1).
17. Attach the cylinder assembly (key 1) to the cylinder flange with the cap screws (key 3).
Size 130 has a mark on the cylinder flange that must align with a mark near the top of the housing flange.
18. For Size 30, 40, and 68 actuators, PlacetheO-ring(key5)inthecylindercap,replacethecylindercap(key4),and
secure it to the cylinder assembly with the cap screws (key 6). Tighten all cap screws to the torques specified in
table 3.
19. I nstall the hub (key 30) plus bushing (key 32) into the cover (key 34), and secure with the retaining ring (key 31).
20. R eplace the travel indicator scale (key 36), and secure it with the self-tapping screws (key 37). Install the travel
indicator (key 38), and secure it with the self-tapping screws (key 39).
21. Note the valve disc or ball position and direction of rotation.
WARNING
To avoid possible personal injury, do not stroke the actuator while the cover (key 34) is off.
a. If no handwheel actuator is to be used, position the travel indicator (key 38) according to the valve disc or ball
position just noted. Replace the cover (key 34) and secure it with the cap screws and washers (key 35 and 76). If
the holes in the cover and housing do not align, temporarily loosen the cap screws (key 24) and shift the housing
slightly. Do not stroke the actuator while the cover is off.
b. If the actuator is equipped with a manual handwheel actuator, refer to the separate instruction manual for
mounting procedures.
22. If a positioner is to be used, refer to the separate valve positioner instruction manual for proper installation.
23. Follow the instructions in the Adjustment section for correct actuator turnbuckle adjustment.
Locking Mechanism
To add the locking mechanism to an existing actuator, purchase the retrofit kit to install this modification or order
individual parts from your Emerson Process Management sales office. Replacement parts are shown in the Parts List