Instruction Manual
D100324X012
1061 F & G Actuator
October 2012
3
Educational Services
For information on available courses for 1061 Style F and G actuators, as well as a variety of other products, contact:
Emerson Process Management
Educational Services, Registration
P.O. Box 190; 301 S . 1
st
Ave.
Marshalltown, IA 50158-2823
Phone: 800-338-8158 or
Phone: 641-754-3771
FAX: 641-754-3431
Principle of Operation
Piston movement is accomplished by loading air pressure on one side of the piston, and unloading air pressure from
the other side of the piston. If no positioner is used with the control valve, a loading device, such as a 4-way switching
valve, must be provided. Such a device is not furnished with the actuator.
Refer to the separate valve positioner instruction manual for the 1061 actuator principle of operation with positioner.
Installation
When an actuator and valve are shipped together, the actuator is normally mounted on the valve. Follow the valve
instructions when installing the control valve in the pipeline. If the actuator is shipped separately or if it is necessary to
mount the actuator on the valve, perform the procedures presented in the Actuator Mounting section.
WARNING
To avoid personal injury, always wear protective gloves, clothing, and eyewear when performing any installation
operations.
To avoid personal injury or property damage caused by bursting of pressure retaining parts, be certain the service
conditions do not exceed the limits given in table 1 or on the nameplate. Use pressure limiting or pressure relieving devices
to prevent the cylinder pressure from exceeding the maximum allowable cylinder operating pressure.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
Actuator Mounting
Use the following steps to connect a valve and actuator that have been ordered separately, or if the valve or actuator
were separated for maintenance purposes.
Key numbers used in this procedure are shown in figures 8, 9 and 11.