Strany 1 - User’s Guide

Battery Monitor Data Manager User’s Guide 3103 No. Andrews Ave. Ext. Pompano Beach, FL 33064 Tel: (954) 623-6660 Fax: (95

Strany 2

ix Table of Figures IMPORTANT NOTE: The drawings or figures in this manual may not be the most recent revision and are included for reference only.

Strany 3

Programming Battery Setup for the BDS 18-10 Standard or Average - Normally select Standard. If the charger employs digital control of battery voltage

Strany 4

Programming Battery Setup for the BDS 18-11 Cell Resistance Threshold - Global applies the alarm level in the Cell Resistance (microhms) field to all

Strany 5

Programming Battery Setup for the BDS 18-12 High Cell Voltage Warning (volts) - Type a value between the Low Cell Voltage and High Cell Voltage level

Strany 6 - Table of Contents

Programming Battery Setup for the BDS 18-13 Remote Reporting - When selected, causes the monitor to report the alarm. When not selected, reporting is

Strany 7

Programming Battery Setup for the BDS 18-14 18.5. Battery Setup: System (BDS) String View > Setup|Battery|System The Thermal Runaway and Hardware

Strany 8

Programming Battery Setup for the BDS 18-15 Temperature Delta A temperature delta can be set to identify the difference in temperature between two t

Strany 9

Programming Battery Setup for the BDS 18-16 18.6. Battery Setup: Discharge (BDS) String View > Setup|Battery|Discharge The following appear on th

Strany 10 - Table of Figures

Programming Battery Setup for the BDS 18-17 Note: If using the Current Mode, the minimum threshold Level to detect discharges must be at least 5% of

Strany 11

Programming Battery Setup for the BDS 18-18 18.7. Battery Setup: Digital Input (BDS) String View > Setup|Battery|Digital Input The Digital Input d

Strany 12

Programming Battery Setup for the BDS 18-19 18.8. Battery Setup: Digital Output (BDS) String View > Setup|Battery|Digital Output The Digital Outpu

Strany 13

x Figure 44. Check Settings - Digital Output (MPM) ... 16-8 Figure 45

Strany 14

Programming Battery Setup for the BDS 18-20 18.9. Battery Setup: LGS (BDS) String View > Setup|Battery|LGS Leibert Global Services (LGS) offers a

Strany 15 - 1. Safety Information

Selecting the Database Range 19-1 19. Selecting the Database Range String Status > Setup|Database Range To select a database range before connect

Strany 16 - 2. System Requirements

Connecting to a Battery Location 20-1 20. Connecting to a Battery Location This section describes how to connect the BMDM program to a location. At

Strany 17 - String Status Screen Buttons

Viewing Battery and Monitor Status 21-1 21. Viewing Battery and Monitor Status At program start, the String Status screen lists all available monito

Strany 18 - 4.3. Starting the Program

Viewing Battery and Monitor Status 21-2 21.2. String Status Screen At start-up, the BMDM displays the String Status screen. The first time the progra

Strany 19

Viewing Battery and Monitor Status 21-3 Monitor Status - The Monitor Status column can report ten conditions, which do not have priority ratings assi

Strany 20

Viewing Battery and Monitor Status 21-4 String Status > Extract all data or String Status > Right click a string name | Extract data The Extr

Strany 21 - 4.6. Default Passwords

Viewing Battery and Monitor Status 21-5 21.4. Summary Screen String Status > Summary or View|Summary The Summary dialog box displays a status su

Strany 22 - 4.7. Computer Types

Viewing Battery and Monitor Status 21-6 Alarm Detail - A computer polling or receiving an alarm call from a monitor receives and displays this inform

Strany 23 - 4.8. Changing Computer Type

Viewing Battery and Monitor Status 21-7 21.7. Cell Voltage (String View Screen) String View > Cell voltage (default) The String View Cell Voltage

Strany 24 - 4.10. Help Screens

xi Figure 101. Trend Intercell Resistance Setup ... 22-7 Fi

Strany 25 - 5. Using Configure Station

Viewing Battery and Monitor Status 21-8 The String Status box on the bottom left of the String View screen can report nine conditions. Priority S

Strany 26 - Using Configure Station

Viewing Battery and Monitor Status 21-9 String View > Start resistance test or Stop resistance test or Get test results To start a resistance te

Strany 27

Viewing Battery and Monitor Status 21-10 21.9. Historical Graphs String View > Cell voltage or Cell resistance or Intercell resistance When the BM

Strany 28

Viewing Battery and Monitor Status 21-11 String View > File|Export (xls) then History The Export History (Voltage) function allows you to export r

Strany 29

Viewing Battery and Monitor Status 21-12 Figure 85. Trend Menu On the pop-up menu, click Trend then Cell or Average to display the trend analysis g

Strany 30 - Practical Theory

Viewing Battery and Monitor Status 21-13 String View > View alarm or View|Alarm then, if not displayed, Get current alarms or View|Current Ala

Strany 31 - 6.2. Local Computer

Viewing Battery and Monitor Status 21-14 Figure 88. Historical Alarm List String View > View alarm or View|Alarm then Select historical alarms

Strany 32 - 6.4. Facility Monitor

Viewing Battery and Monitor Status 21-15 21.13. Alarm Acknowledge String View > View alarm or View|Alarm then Acknowledge alarm If the alarm

Strany 33

Viewing Battery and Monitor Status 21-16 The BDS and MPM All Discharges screens are similar, except the MPM screen has the MPM Current to Include in

Strany 34

Viewing Battery and Monitor Status 21-17 Cell Detail area - To manually select cells to include in the report, click the cells in the list or click A

Strany 35 - Service computer types

xii Figure 156. Report (Comm Asst) ... 29-1

Strany 36

Viewing Battery and Monitor Status 21-18 21.14.1. Discharge Replay String View > View|Load test or Discharge then Discharge replay or View|Disc

Strany 37

Viewing Battery and Monitor Status 21-19 21.14.2. Discharge Curve String View > View|Load test or Discharge then Discharge curve or View|Discha

Strany 38

Viewing Battery and Monitor Status 21-20 Figure 93. Curve Option In Curve 1, 2 or 3, select Overall Voltage, Discharge Current or Cell Voltage curve

Strany 39

Viewing Battery and Monitor Status 21-21 21.14.3. Summary String View > View|Load test or Discharge then Summary or View|Summary Select Summary

Strany 40

Viewing Battery and Monitor Status 21-22 21.15. Cell Memo / String Memo Cell Memo or String Memo saves notes for a cell or string to the database us

Strany 41 - 9.2. Data Storage in the BDS

Using the Report Generator 22-1 22. Using the Report Generator The BMDM Report Generator uses BMDM data files to create reports. After a BMDM-contro

Strany 42

Using the Report Generator 22-2 Select Show Average Trend to generate a graph that shows the average voltage of all the cells in the string for each

Strany 43

Using the Report Generator 22-3 22.2. Detail Cell Resistance Report String View > View|Reports|Detail|Cell Resistance To create a Detail Cell Resi

Strany 44 - 11. Selecting Preferences

Using the Report Generator 22-4 22.3. Detail Intercell Resistance Report String View > View|Reports|Detail|Intercell Resistance To create a Detail

Strany 45 - Selecting Preferences

Using the Report Generator 22-5 22.4. Trend Cell Voltage Report String View > View|Reports|Trend|Cell Voltage To create a Trend Cell Voltage repor

Strany 47 - Setting Communications

Using the Report Generator 22-6 Data Sets area - To manually select cells to include in the report, click the cells in the list or click All to selec

Strany 48 - Figure 23. Email Setup

Using the Report Generator 22-7 22.6. Trend Intercell Report String View > View|Reports|Trend|Intercell To create a Trend Intercell report, click

Strany 49 - 13.1. Testing Email

Using the Report Generator 22-8 22.7. Trend Overall Voltage Report String View > View|Reports|Trend|Overall Voltage To create a Trend Overall Volt

Strany 50 - Password

Using the Report Generator 22-9 22.8. Trend Temperature Report String View > View|Reports|Trend|Temperature To create a Trend Temperature report,

Strany 51 - 14.2. System Setup: Customer

Using the Report Generator 22-10 22.10. Discharge Report String View > View|Reports|Discharge To create a Discharge report, click Discharge. The

Strany 52 - 14.3. System Setup: Location

Using the Report Generator 22-11 Select Tabular to create a Tabular report, which is the same as a standard report, but in a spreadsheet format, with

Strany 53 - 14.4. System Setup: Battery

Using the Report Generator 22-12 22.12. Summary Report String Status > Summary report or String View > View|Reports|Summary [see text] To cr

Strany 54

Using the Report Generator 22-13 Threshold Deviation area - Select Include to include the threshold deviation report. Select Start New Page to insert

Strany 55 - 14.5. System Setup: String

Using the Preview Screens 23-1 23. Using the Preview Screens [Previously described Setup screen] > Preview After all report parameters are select

Strany 56 - 14.6. System Setup: Link

Using the Preview Screens 23-2 23.1. Saving a Report in Archive (ZRF) Format Preview screen > Save Archive The Report Generator can save a report

Strany 57

Safety Information 1-1 1. Safety Information • You must read and understand these safety precautions and those elsewhere in this manual before insta

Strany 58

Using the Web Report Generator 24-1 24. Using the Web Report Generator Every 24 hours, the Web Report Generator automatically creates and saves an e

Strany 59

Using the Web Report Generator 24-2 Maintenance Recommendation area - Select Include to include the maintenance recommendation report. Select Start N

Strany 60

Using the Web Report Generator 24-3 24.2. Generating an Executive Summary Report String Status > Reports|Generate If enabled on Setup|Preferences,

Strany 61

Calibration 25-1 25. Calibration String View > Setup|Calibration To ensure reliability of readings, Albér recommends that a qualified technician

Strany 62

Calibration 25-2 There are four columns on the Calibration dialog box: Measurement Point, Measured Value, A/D Counts, and Calibration Factor. Measu

Strany 63 - 14.9. System Setup: Password

MPM Diagnostics 26-1 26. MPM Diagnostics String View > Diagnostics|Item The diagnostics are used for production testing, but may help troubleshoo

Strany 64

MPM Diagnostics 26-2 26.2. Self Test (MPM) String View > Diagnostics|Self Test Self Test reads an MPM status register and displays the parameter

Strany 65

MPM Diagnostics 26-3 26.3. Load Module (MPM) String View > Diagnostics|Load Module The Load Module diagnostic tests each load connection to the b

Strany 66

MPM Diagnostics 26-4 26.4. DIP Switch (MPM) String View > Diagnostics|DIP Switch The DIP Switch diagnostic confirms each position of the DIP sw

Strany 67 - 16. Check Settings Screens

MPM Diagnostics 26-5 26.5. Indicator (MPM) String View > Diagnostics|Indicator This diagnostic tests front panel LED operation. To open Indicator

Strany 68 - Check Settings Screens

System Requirements 2-1 2. System Requirements These are the minimum requirements for the BMDM (Battery Monitor Data Manager) program. Microsoft Win

Strany 69

MPM Diagnostics 26-6 26.7. Memory (MPM) String View > Diagnostics|Memory To open Memory Diagnostics, select Memory. Figure 120. Diagnostics - M

Strany 70

MPM Diagnostics 26-7 26.8. Contacts (MPM) String View > Diagnostics|Contacts This diagnostic checks the external alarm contacts, charger contacts

Strany 71

MPM Diagnostics 26-8 26.9. Intertier (MPM) String View > Diagnostics|Intertier The Intertier diagnostic monitors the signal on each intertier inp

Strany 72

BDS Diagnostics 27-1 27. BDS Diagnostics String View > Diagnostics|Item The diagnostics are used for production testing, but may help troubleshoo

Strany 73

BDS Diagnostics 27-2 Dial Tone (BDS Controller) - Confirms the telephone is connected. If connected via a multiplexer, this field indicates Failed a

Strany 74

BDS Diagnostics 27-3 27.3. Load Module (BDS) String View > Diagnostics|Load Module The Load Module diagnostic tests each load connection to the b

Strany 75

BDS Diagnostics 27-4 To run the diagnostic that can confirm the direction of the current transducer (CT), click the CT Polarity tab on the dialog box

Strany 76

BDS Diagnostics 27-5 27.4. DIP Switch (BDS) String View > Diagnostics|DIP Switch The DIP Switch diagnostic confirms each position of the DIP swit

Strany 77

BDS Diagnostics 27-6 27.5. Indicator (BDS) String View > Diagnostics|Indicator This diagnostic tests front panel LED operation. To open Indicator

Strany 78

BDS Diagnostics 27-7 27.7. Memory (BDS) String View > Diagnostics|Memory To open Memory Diagnostics, select Memory. Figure 129. Diagnostics -

Strany 79

String Status Screen Buttons 3-1 3. String Status Screen Buttons This page describes buttons on the String Status screen, which appears when the BMDM

Strany 80

BDS Diagnostics 27-8 27.8. Contacts (BDS) String View > Diagnostics|Contacts This diagnostic checks the external critical and maintenance alarm c

Strany 81

BDS Diagnostics 27-9 Intertier Voltage (mvolts) - This column indicates the voltages being sent. This screen displays up to 15 intertiers for the BDS

Strany 82

BDS Diagnostics 27-10 27.11. Resistance Testing Multiple DCM Units String View > Cell Resistance or Intercell Resistance tab > Diagnostics|R-T

Strany 83

Upgrades 28-1 28. Upgrades String View > Setup|Upgrade Firmware or Upgrade DCM Firmware E2 (electrically erasable) memory on the MPM and SRAM memo

Strany 84

Commissioning Assistant 29-1 29. Commissioning Assistant View|Reports|Commissioning Report The Commissioning Assistant creates a report that is extre

Strany 85

Commissioning Assistant 29-2 29.2. Monitor Pre-Power Check List Figure 136. Monitor Pre-Power Screen (typical) The text at the top of the Monitor Pre

Strany 86

Commissioning Assistant 29-3 29.3. Starting the Assistant for an Existing String View|Reports|Commissioning Report This section describes how to start

Strany 87

Commissioning Assistant 29-4 29.4. Completing the Commissioning Assistant After opening the commissioning assistant, complete the remaining screens as

Strany 88

Commissioning Assistant 29-5 29.4.2. Equipment Owner Screen Figure 140. Equipment Owner (Comm Asst) Click the Equipment Owner button. Complete the f

Strany 89

Commissioning Assistant 29-6 29.4.3. Post Power Check Screen Figure 141. Post Power Check Screen (BDS-256 only) (Comm Asst) Click the Post Power Che

Strany 90 - Battery Setup: LGS (MPM)

Program Installation and Options 4-1 4. Program Installation and Options When installing the BMDM, you will choose Install BMDM Manager. Other screen

Strany 91

Commissioning Assistant 29-7 29.4.4. Send Battery Setup Screen Figure 142. Send Battery Setup (Comm Asst) Click the Send Battery Setup button. Verif

Strany 92

Commissioning Assistant 29-8 29.4.6. Serial Numbers Screen Figure 144. Serial Numbers (Comm Asst) Click the Serial Numbers button. To upload the ser

Strany 93

Commissioning Assistant 29-9 29.4.8. Check Overall Voltage Screen Figure 146. Check Overall Voltage (Comm Asst) Click the Check Overall Voltage butt

Strany 94

Commissioning Assistant 29-10 29.4.10. Base Data - Cell Voltage Screen Figure 148. Base Data - Cell Voltage (Comm Asst) Click the Base Data - Cell V

Strany 95

Commissioning Assistant 29-11 29.4.12. Check Temperature Screen Figure 150. Check Temperature (Comm Asst) Click the Check Temperature button. Type t

Strany 96

Commissioning Assistant 29-12 Click the Check Discharge Current button. Verify the ±15VDC voltage supply is connected to the current transducer. Type

Strany 97

Commissioning Assistant 29-13 29.4.15. Check Intercell Screen (BDS Only) Figure 153. Check Intercell (Comm Asst) Click the Check Intercell button. I

Strany 98

Commissioning Assistant 29-14 Figure 155. Save Base Line and Send Thresholds Data – Cell/Intertier/Inter-Cell Resistance (Comm Asst) Based on a 12 vo

Strany 99

Commissioning Assistant 29-15 Click the Report button. Text on the screen displays the path and folder where the report is saved. To view pages in the

Strany 100

Commissioning Assistant 29-16 29.5. Emailing a Report The completed Commissioning Agent report must be sent to Alber as an email attachment for warran

Strany 101

Program Installation and Options 4-2 4.4. Configuring BMDM to Run as a Windows Service The BMDM can be run as a service so the application will conti

Strany 102

Error Codes 30-1 30. Error Codes The following error messages may appear when running the BMDM program. CODE MESSAGE SITUATION 1 The database canno

Strany 103

Error Codes 30-2 CODE MESSAGE SITUATION 203 The currently selected COM Port, COM <ComPortNum>, is already in use by another program. Press OK a

Strany 104

Index % above baseline field on detail cell resistance s/u ... 22-3 on trend cell resistance s/u ... 22-6 24/7 on c

Strany 105

on battery s/u general BDS ... 18-3 on battery s/u general MPM ... 17-3 autopolling ...

Strany 106

cell # column on battery s/u parameters BDS ... 18-8 cell # field on battery s/u parameters MPM ... 17-4 cell # label start from area

Strany 107

for the MPM ... 17-1 modem to a location ... 20-1 network to a location ...

Strany 108

detail intercell resistance s/u ... 22-4 deviation storage thresholds area on battery s/u discharge MPM ... 17-10 diagno

Strany 109

on tech detail summary report s/u ... 24-2 d. time column on summary s/u ... 22-13 on tech detail summary report s/u ..

Strany 110

on battery s/u general BDS ... 18-3 on battery s/u general MPM ... 17-3 force all strings direct connection ck box on

Strany 111 - Selecting the Database Range

indicator diagnostics MPM screen ... 27-6 individual button on battery s/u float alarms BDS ... 18-11 on battery s/u float alarms MPM ...

Strany 112 - 20.3. Connecting via Network

i 1. WARRANTY AND LIMITATION OF LIABILITY LIMITED WARRANTY. Albércorp warrants that the software product will perform in accordance with the accomp

Strany 113

Program Installation and Options 4-3 Figure 3. BMDM and AlwaysUp Running as a Service 4. Type Ctrl+Shift+Esc to open the task manager. Check for

Strany 114 - 21.2. String Status Screen

l. system setup screen ... 14-3 system s/u ... 14-3 lock check box ...

Strany 115

n. connection area on communication s/u ... 12-1 n. port field on system s/u link ...

Strany 116

phone number field on system s/u link ... 14-7 PIO status on self test diagnostics BDS . 27-2 polling ...

Strany 117 - 21.4. Summary Screen

on self test diagnostics MPM ... 26-2 sample database ... 4-1 ck box on preferences ...

Strany 118 - 21.6. String View Screens

s. date/time column on all discharges ... 21-16 on discharge s/u ... 22-11 s. field for databa

Strany 119

technician detail summary rpt s/u screen ... 24-1 technician report discharges area

Strany 120

Program Installation and Options 4-4 6. It is recommended to replace the regular BMDM shortcut on the desktop with the Run BMDM Service in Session s

Strany 121

Program Installation and Options 4-5 4.7. Computer Types The first time the program runs, a question about computer type appears. Figure 5. Select

Strany 122 - 21.9. Historical Graphs

Program Installation and Options 4-6 4.8. Changing Computer Type The Select Computer Type box appears only the first time you install the program. Yo

Strany 123 - 21.11. Trend Analysis

Program Installation and Options 4-7 4.9. File Types The BMDM program uses several file extensions. MDB ... An Access database file that stor

Strany 124 - 21.12. Alarm Data

Using Configure Station 5-1 5. Using Configure Station The Configure Station dialog boxes for a Local, Central or Service computer facilitate setting

Strany 125

Using Configure Station 5-2 Figure 9. Configure Station - Select Number of Modems If communicating via modem, select the number of modems in use. Fo

Strany 126

Using Configure Station 5-3 Figure 12. Configure Station - Set Station Phone Number If communicating via modem, type the telephone number of the co

Strany 127 - 21.14. Discharge Data

Using Configure Station 5-4 Figure 15. Configure Station - Email Setup If sending alarms via e-mail, complete this dialog box. Refer to Setting Up a

Strany 128

Using Configure Station 5-5 Figure 18. Configure Station - Information If running the BMDM for the first time with an Access database, this box ope

Strany 129

ii EXPORT LAW ASSURANCES. You acknowledge and agree that the Software is subject to restrictions and controls imposed by the United States Export Adm

Strany 130 - 21.14.1. Discharge Replay

Practical Theory: Understanding Computer Types 6-1 Practical Theory 6. Understanding Computer Types When installing the BMDM program, select one of

Strany 131 - 21.14.2. Discharge Curve

Practical Theory: Understanding Computer Types 6-2 6.2. Local Computer For continuous, on-site display of battery information, use a Local computer.

Strany 132 - Figure 93. Curve Option

Practical Theory: Understanding Computer Types 6-3 6.3. Service Computer The Service computer can be a desktop or notebook computer temporarily conne

Strany 133 - 21.14.3. Summary

Practical Theory: Understanding Polling, Extraction and Backup 7-1 Practical Theory 7. Understanding Polling, Extraction and Backup This chapter expl

Strany 134

Practical Theory: Understanding Polling, Extraction and Backup 7-2 7.3. Polling and Extraction Notes Auto Polling via Modem with a Central Computer -

Strany 135 - Using the Report Generator

Practical Theory: Understanding Polling, Extraction and Backup 7-3 The following table summarizes polling, extraction and backup for Central, Local,

Strany 136

Practical Theory: Understanding System Installation 8-1 Practical Theory 8. Understanding System Installation This section describes how to set up th

Strany 137

Practical Theory: Understanding System Installation 8-2 8.2. Connecting Using a Central Computer The following describes how to set up an MPM or BDS

Strany 138

Practical Theory: Understanding System Installation 8-3 8.3. Connecting Using a Service Computer The following describes how to set up a computer as

Strany 139

Practical Theory: Understanding System Installation 8-4 • If the Service computer is a remote connection (off-site) computer for viewing battery dat

Strany 140

iii 4. REGULATORY INFORMATION Type of Service: The MPM Series and the BDS Series equipment is designed to be used on standard device telephone lines

Strany 141 - 22.6. Trend Intercell Report

Practical Theory: Understanding How Data is Stored 9-1 Practical Theory 9. Understanding How Data is Stored This section describes how the BMDM proce

Strany 142

Practical Theory: Understanding How Data is Stored 9-2 9.2. Data Storage in the BDS Data in the BDS is stored in nonvolatile SRAM memory, which retai

Strany 143 - 22.9. Trend Intertier Report

Practical Theory: Understanding the Time to Go Algorithm 10-1 Practical Theory 10. Understanding the Time to Go Algorithm The battery Amp-hour (Ah)

Strany 144 - 22.10. Discharge Report

Practical Theory: Understanding the Time to Go Algorithm 10-2 Although the Time to Go calculation may offer a close estimate, many other battery para

Strany 145 - 22.11. Alarm Report

Selecting Preferences 11-1 11. Selecting Preferences String Status > Setup|Preferences At any time, you may open the Preferences dialog box to ch

Strany 146 - 22.12. Summary Report

Selecting Preferences 11-2 String View Network Grouping area - When connected to a string, a drop-down list at the top of the screen shows the name o

Strany 147

Setting Communications 12-1 12. Setting Communications String Status > Setup communication or Setup|Communication Select this dialog box to def

Strany 148 - Using the Preview Screens

Setting Communications 12-2 Disable Auto Polling / Auto Answering - For computer–monitor connection via RS-232 or network, not selecting this box ena

Strany 149 - 23.2. Printing a Report

Setting Up an Email Account 13-1 13. Setting Up an Email Account String Status > Setup|Email Setup Use Email Setup to set up the account under wh

Strany 150

Setting Up an Email Account 13-2 13.1. Testing Email String Status > Setup|Email Setup|Test The Test Email box tests the settings on the Email Set

Strany 152 -  Reader

Setting Up a New MPM or BDS System 14-1 14. Setting Up a New MPM or BDS System String Status > Setup system or Setup|System BMDM setup involves

Strany 153 - 25. Calibration

Setting Up a New MPM or BDS System 14-2 14.2. System Setup: Customer String Status > Setup|System|Customer Use the Customer dialog box to add new

Strany 154 - Calibration

Setting Up a New MPM or BDS System 14-3 14.3. System Setup: Location String Status > Setup|System|Location Before completing the Location dialog b

Strany 155 - 26. MPM Diagnostics

Setting Up a New MPM or BDS System 14-4 14.4. System Setup: Battery String Status > Setup|System|Battery The Battery dialog box assigns a battery

Strany 156 - 26.2. Self Test (MPM)

Setting Up a New MPM or BDS System 14-5 Cell # Label Start From - This allows the reverse numbering of cells. Select Most Negative Cell when the cell

Strany 157 - 26.3. Load Module (MPM)

Setting Up a New MPM or BDS System 14-6 14.5. System Setup: String String Status > Setup|System|String The String dialog box assigns a string name

Strany 158 - 26.4. DIP Switch (MPM)

Setting Up a New MPM or BDS System 14-7 Start Cell # (MPM) (required) - Type the first cell number for the first string in the battery being monitore

Strany 159 - 26.6. Digital Port (MPM)

Setting Up a New MPM or BDS System 14-8 Network - Select if the monitor connects to the computer via network. Complete IP Address, Network Port, Net

Strany 160 - 26.7. Memory (MPM)

Setting Up a New MPM or BDS System 14-9 14.7. System Setup: Reporting String Status > Setup|System|Reporting The Reporting dialog box selects the

Strany 161 - 26.8. Contacts (MPM)

Setting Up a New MPM or BDS System 14-10 Delay (Seconds) - If using a numeric pager, type the delay in seconds before the numeric message is sent.

Strany 162 - 26.9. Intertier (MPM)

v Table of Contents 1. SAFETY INFORMATION ...

Strany 163 - 27. BDS Diagnostics

Setting Up a New MPM or BDS System 14-11 Include Warnings, Memory Full and Inactive - Select these check boxes to contact and require acknowledgement

Strany 164 - BDS Diagnostics

Setting Up a New MPM or BDS System 14-12 Contacts - To type persons' names to add to a list of potential contacts, click New on the right panel

Strany 165 - 27.3. Load Module (BDS)

Setting Up a New MPM or BDS System 14-13 Page On Alarm - Select to display the Page Report Alarm Event box on error and send alarm notification to a

Strany 166

Setting Up a New MPM or BDS System 14-14 Add Names to Contact List - To add people to a Contact List, first select a group name from the drop-down Co

Strany 167 - 27.4. DIP Switch (BDS)

Synchronizing Using Check Settings 15-1 15. Synchronizing Using Check Settings The location, battery, and string names are key for letting a compute

Strany 168 - 27.6. Digital Port (BDS)

Synchronizing Using Check Settings 15-2 Note on Network Settings - Network parameters do not upload using Check Settings|General. To change the IP Ad

Strany 169 - 27.7. Memory (BDS)

Synchronizing Using Check Settings 15-3 15.1. Connecting With a Service Computer This section describes how to connect to a monitor when site details

Strany 170 - 27.9. Intertier (BDS)

Check Settings Screens 16-1 16. Check Settings Screens Active check: String Status > Connection then Setup|Check Settings|dialog box Offline: S

Strany 171

Check Settings Screens 16-2 The Check Settings|Parameters dialog boxes for the MPM and BDS are shown below. Figure 36. Check Settings - Parameters

Strany 172 - Figure 133. Select DCM

Check Settings Screens 16-3 The Check Settings|Test Parameters dialog box for the MPM and BDS is shown below. Figure 38. Check Settings - Test Par

Strany 173 - 28. Upgrades

vi 15.1. Connecting With a Service Computer ... 15-3 16. CHECK SET

Strany 174 - 29. Commissioning Assistant

Check Settings Screens 16-4 The Check Settings|Float Alarms dialog boxes for the MPM and BDS are shown below. Figure 39. Check Settings - Float Al

Strany 175 - Commissioning Assistant

Check Settings Screens 16-5 Figure 41. Check Settings - Float Alarms (BDS)

Strany 176

Check Settings Screens 16-6 The Check Settings|Discharge dialog box for the MPM and BDS is shown below. Figure 42. Check Settings - Discharge (MPM

Strany 177

Check Settings Screens 16-7 The Check Settings|Digital Input dialog boxes for the MPM and BDS-256 are shown below. The BDS Digital Input tab and dial

Strany 178

Check Settings Screens 16-8 The Check Settings|Digital Output dialog boxes for the MPM and BDS-256 are shown below. The Digital Output tab and dialog

Strany 179

Check Settings Screens 16-9 The Check Settings|Calibration dialog boxes for the MPM and BDS are shown below. The BDS Calibration dialog box reports t

Strany 180

Check Settings Screens 16-10 The Check Settings|LGS dialog box for the MPM and BDS is shown below. Figure 49. Check Settings - LGS (MPM / BDS)

Strany 181

Check Settings Screens 16-11 16.1. Check Settings Screens in Controller BDS Only: String Status > Connection then <CTRL>Setup|Check Settin

Strany 182

Programming Battery Setup for the MPM 17-1 17. Programming Battery Setup for the MPM From String Status, click Connection to display the String Vi

Strany 183

Programming Battery Setup for the MPM 17-2 17.1. Battery Setup: General (MPM) String View > Setup|Battery|General The following appear on the Gene

Strany 184

vii 22.9. Trend Intertier Report ... 22-9

Strany 185

Programming Battery Setup for the MPM 17-3 Float Current Multiplier - When a series of batteries is connected with more than one cable, it may not b

Strany 186

Programming Battery Setup for the MPM 17-4 17.2. Battery Setup: Parameters (MPM) String View > Setup|Battery|Parameters On Parameters, select the

Strany 187 - 29.4.17. Report Screen

Programming Battery Setup for the MPM 17-5 17.3. Battery Setup: Test Parameters (MPM) String View > Setup|Battery|Test Parameters The following ap

Strany 188

Programming Battery Setup for the MPM 17-6 Standard or Average - Normally select Standard. If the charger employs digital control of battery voltage,

Strany 189 - 29.5. Emailing a Report

Programming Battery Setup for the MPM 17-7 Figure 55. Cell Resistance Alarm Levels Setup (MPM) Cell Resistance Alarm Levels box - To set Alarm Leve

Strany 190 - 30. Error Codes

Programming Battery Setup for the MPM 17-8 Percentage for Warning - Determines the violation threshold that causes a Warning battery status. The valu

Strany 191 - Error Codes

Programming Battery Setup for the MPM 17-9 17.5. Battery Setup: Discharge (MPM) String View > Setup|Battery|Discharge The following appear on the

Strany 192

Programming Battery Setup for the MPM 17-10 Voltage mode allows data recording during recharge, since data logging does not stop until the voltage go

Strany 193

Programming Battery Setup for the MPM 17-11 17.6. Battery Setup: Digital Input (MPM) String View > Setup|Battery|Digital Input The MPM has 16 dig

Strany 194

Programming Battery Setup for the MPM 17-12 17.7. Battery Setup: Digital Output (MPM) String View > Setup|Battery|Digital Output The MPM has three

Strany 195

viii 29.4.16. Base Data - Cell Resistance Screen ... 29-13 29.4.17. Repo

Strany 196

Programming Battery Setup for the MPM 17-13 Battery Setup: LGS (MPM) String View > Setup|Battery|LGS Leibert Global Services (LGS) offers a servic

Strany 197

Programming Battery Setup for the BDS 18-1 18. Programming Battery Setup for the BDS From String Status, click Connection to display the String Vi

Strany 198

Programming Battery Setup for the BDS 18-2 18.1. Battery Setup: General (BDS) String View > Setup|Battery|General The following appear on the Gen

Strany 199

Programming Battery Setup for the BDS 18-3 Float Current Multiplier - When a series of batteries is connected with more than one cable, it may not b

Strany 200

Programming Battery Setup for the BDS 18-4 18.2. Battery Setup: Parameters (BDS) String View > Setup|Battery|Parameters The following appear on t

Strany 201

Programming Battery Setup for the BDS 18-5 Config DCM Cells LS/D R/LS RLLS SS# 1x198x1V 1 44 2 22 22 1 2 44 2 22 22 3 3 44 2 22 22 5 4 44 2 22 22

Strany 202

Programming Battery Setup for the BDS 18-6 Config DCM Cells LS/D R/LS RLLS SS# 1x198x1V 1 44 2 22 22 1 2 44 2 22 22 3 3 44 2 22 22 5 4 44 2 22 22

Strany 203

Programming Battery Setup for the BDS 18-7 Config DCM Cells LS/D R/LS RLLS SS# 1x244x2V 1 48 2 24 24 1 2 48 2 24 24 3 3 48 2 24 24 5 4 48 2 24 24

Strany 204

Programming Battery Setup for the BDS 18-8 Parameter / Enabled - The OV, DC and FC parameters are assigned to DCM #1. Select Enabled to view the para

Strany 205

Programming Battery Setup for the BDS 18-9 18.3. Battery Setup: Test Parameters (BDS) String View > Setup|Battery|Test Parameters The following ap