Emerson CMF200A Uživatelský manuál Strana 4

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 60
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 3
4 Micro Motion
®
ELITE
®
Flow and Density Meters
Accuracy and repeatability
Electronics option
Model 2400S,
enh. core processor
Other MVD transmitter,
std. core processor
Mass and
volume flow
(1)
(1) Accuracy options vary by model. Models CMF010, CMFS010, CMFS015, sensors with Model 2200S transmitter, and all high-
temperature models have fewer accuracy options. See Ordering information on page 54.
Liquid Accuracy
(2)
(2) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on
reference conditions of water at 68 to 77 °F (20 to 25 °C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.
±0.05% of rate
(3)(4)(5)
(3) When flow rate is less than zero stability / 0.0005, accuracy = ±[(zero stability / flow rate) × 100]% of rate, and
repeatability = ±[½(zero stability / flow rate) × 100]%.
(4) When ordered with the ±0.10% factory calibration option, accuracy on liquid = ±0.10% when flow rate
zero stability / 0.001. When flow
rate < zero stability / 0.001, accuracy = ±[(zero stability / flow rate) × 100]% of rate and repeatability = ±[½(zero stability / flow rate) ×
100]% of rate.
(5) For cryogenic applications (below –100 °C), mass flow accuracy is ±0.35% of rate.
±0.10% of rate
(6)(5)
(6) When flow rate is less than zero stability / 0.001, accuracy = ±[(zero stability / flow rate) × 100]% of rate and
repeatability = ±[½(zero stability / flow rate) × 100]% of rate.
Repeatability ±0.025% of rate ±0.05% of rate
Gas Accuracy ±0.35% of rate
(7)
(7) When flow rate is less than zero stability / 0.0035, accuracy equals ±[(zero stability / flow rate) × 100]% of rate and repeatability equals
±[½(zero stability / flow rate) × 100]% of rate.
±0.35% of rate
Repeatability ±0.20% of rate ±0.20% of rate
Density
(1)(8)
(8) Specifications for ±0.0002 g/cm
3
(±0.2 kg/m
3
) density accuracy are based on reference conditions of water at 68 to 140 °F (20 to 60 °C)
and 15 to 30 psig (1 to 2 bar).
Liquid Accuracy ±0.0002 g/cm
3
(±0.2 kg/m
3
)
±0.0005 g/cm
3
(±0.5 kg/m
3
)
Repeatability ±0.0001 g/cm
3
(±0.1 kg/m
3
)
±0.0002 g/cm
3
(±0.2 kg/m
3
)
Temperature Accuracy ±1 °C ± 0.5% of reading ±1 °C ± 0.5% of reading
Repeatability ±0.2 °C ±0.2 °C
lb/min kg/h
Zero stability CMFS010M 0.000075 0.002
CMFS010H, P 0.00015 0.004
CMFS015M 0.00037 0.01
CMFS015H, P 0.00073 0.02
CMF010M, H 0.000075 0.002
CMF010P 0.00015 0.004
CMF025 0.001 0.027
CMF050 0.006 0.163
CMF100 0.025 0.680
CMF200 0.08 2.18
CMF300 0.25 6.80
CMF400 1.50 40.91
Zobrazit stránku 3