ACCOL III Function Block Library
Function Block
Name
Description
DIFFERENTIATOR Calculates the rate of change of an input.
DISPLAY Used to congure the Bristol 2 button and 25 button keypad and display connected
to a controller. This will allow an operator to view/change signal data or be allowed
to scroll through lists of signal data based upon their login privileges.
ENCODE This Function Block will do the following:
- Convert packed Julian date/time to REAL values
- Convert REAL values to packed Julian date/time
- Convert system date/time to REAL values
FILE Provides program control to open, close, delete, read and write les
FPV Computes the supercompressibility factor (Fpv) of a gas measured in accordance
with the American Gas Association Report No. NX-19
FUNCTION Performs a table lookup based on array row and column inputs
GENERIC_SERIAL Allows the engineer to write custom serial protocols to third party devices through
message read and write
HILOLIMITER Compares the value of an input to a predened min and max
HILOSELECT Selects the largest and smallest values from a set of inputs.
INTEGRATOR Computes an integral approximation of an input value.
ISO5167 Calculates ow rate for Orice plates, Nozzles, Venturi tubes, and Venturi-nozzle
Primary Devices as specied in the International Organization for Standardization’s
International Standard ISO 5167-1980 (E), 1980 edition.
LEAD_LAG Performs a controlled delay on changes based on a given input. Module can also
be use for simulation of process lag
LIQ Liquids measurements for density ‘A’ and temperature ‘B’ tables 5, 6, 23, 24, 53,
54, 59 and 60. Also, F1 and F1M compressability.
LIST_ELE_NAME Fetches the variable name for a given list element
LIST10, 20, 30, 50 & 100 A list of up to 10, 20, 30, & 50 input or output variables.
MUX Performs a multiplex operation by selecting from a group of inputs, and applying
that selected input to an output.
PDO allows the user to produce pulses of variable width (Pulse Duration Output) at the
digital output eld wiring terminals
PID3TERM Provides a process control algorithm which allows proportional (P), proportional/in-
tegral (PI) or proportional/integral/derivative (PID) modes.
PORT_CTRL Allows the user to manually control the Data Terminal Ready (DTR) output of a
selected communications port. Setting DTR to FALSE will disable the selected port
and place it in low power mode.