Emerson FM-3 Instalační manuál Strana 1

Procházejte online nebo si stáhněte Instalační manuál pro Sítě Emerson FM-3. Emerson FM-3 Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation Manual

P/N 400508-02Revision: A2Date: August 23, 2000© EMERSON Motion Control, Inc. 2000FM-3 Programming Module Installation Manual

Strany 2

viiirelevant safety legislation in the country of use.AC supply isolation deviceThe AC supply must be removed from the drive using an approved isolati

Strany 3 - Installation Manual

ixCustomer Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiiRefere

Strany 5 - Customer Service

1IntroductionFM-3 is a compact and rugged function module that attaches to the front of the E Series drive. It provides eight digital input lines and

Strany 6

2FM-3 Programming Module Installation ManualThe FM-3 stores E Series drive setup parameters within the module itself. This allows you to transfer the

Strany 7 - Document Conventions

3InstallationBasic Installation NotesYou are required to follow all safety precautions during start-up such as providing proper equipment grounding, c

Strany 8 - Reference Materials

4FM-3 Programming Module Installation Manual Figure 4: Detaching the FM-3 from the Drive ConnectionsCautionDo not attach or detach the FM-3 when power

Strany 9 - Safety Considerations

5InstallationSoftware InstallationEmerson Motion Control PowerTools® FM-3 software was designed for users who need access to all setup options and dia

Strany 10

6FM-3 Programming Module Installation Manual3. In the Run dialog box, type a:/setup, where a is the letter assigned to your 3.5" floppy drive.4

Strany 11 - Table of Contents

7InstallationExiting the SoftwareChoose File from the menubar, then click Exit. If you are using the keyboard, press the shortcut key combination Alt+

Strany 13 - Introduction

8FM-3 Programming Module Installation Manual

Strany 14 - Programming Module

9Diagnostics and TroubleshootingDiagnostic DisplayThe diagnostic segment display on the front of the drive shows drive status, FM-3 status, and fault

Strany 15 - Installation

10FM-3 Programming Module Installation ManualFault CodesA number of diagnostic and fault detection circuits are incorporated to protect the drive. Som

Strany 16 - Modbus Communications

11Diagnostics and TroubleshootingInvalid Configuration Button or Input Yes Invalid ConfPower Module Button or Input Yes Power Module High DC Bus Butt

Strany 17 - PC System Configuration

12FM-3 Programming Module Installation ManualFault DescriptionsFlash InvalidThis fault indicates that the firmware checksum has failed. Use the Tools

Strany 18 - Starting the Software

13Diagnostics and TroubleshootingInvalid ConfigurationThe FM was not on this drive during its previous power-up and it is not known if the setup data

Strany 19 - Accessing Help

14FM-3 Programming Module Installation ManualEncoder HardwareIf any pair of encoder lines are in the same state, an encoder line fault is generated. T

Strany 20

15Diagnostics and TroubleshootingFM-3 Specific Fault Descriptions Figure 5: FM-3 display is used to display drive and FM-3 faultsTraj FaultThis fault

Strany 21 - Diagnostic Display

16FM-3 Programming Module Installation ManualBrake OperationMG motor brake operation is controlled by the Brake Release and Brake Control destinations

Strany 22 - Fault Codes

17Diagnostics and TroubleshootingAnalog OutputsThe drive has two 10 bit Analog Outputs which may be used for diagnostics, monitoring or control purpos

Strany 23

Information furnished by EMERSON Motion Control is believed to be accurate and reliable. However, no responsibility is assumed by EMERSON Motion Contr

Strany 24 - Fault Descriptions

18FM-3 Programming Module Installation ManualDiagnostic Analog Output Test PointsThe DGNE cable was designed to be use with either an oscilloscope or

Strany 25

19Diagnostics and Troubleshooting Figure 7: Diagnostic Cable (DGNE) Diagram10 Ohm10 OhmYellowBlack(GND)BlueD/AD/ADGNE CableCommandConnector (J5)DGNE C

Strany 26

20FM-3 Programming Module Installation ManualDrive FaultsThe Active Drive Faults dialog box is automatically displayed whenever a fault occurs. There

Strany 27

21Diagnostics and TroubleshootingThe terms below appear in the list the of common problems you might encounter when working with PowerTools software a

Strany 28 - Brake Operation

22FM-3 Programming Module Installation ManualProgramming Error MessagesThese Red Dot Error messages occur while you are working in the Program View. W

Strany 29 - Analog Outputs

23Diagnostics and TroubleshootingError: A string variable can only be assigned a quoted text stringThe Variable is string. It only accepts types cons

Strany 30 - Analog GND

24FM-3 Programming Module Installation ManualError: Syntax error encounteredParser Error Message. The Parser can not understand your text sequence.Er

Strany 31

25Diagnostics and TroubleshootingError: The destination variable's resolution is less than the resolution of the numberYou attempted to assign a

Strany 32 - Error Messages

26FM-3 Programming Module Installation ManualError: The Selection variable can only be assigned a Selection value.The destination variable only accept

Strany 33

27Diagnostics and TroubleshootingOnline Status IndicatorsGlobal Where Am I ButtonThe Program View, when online and executing a program or sequence of

Strany 34 - Programming Error Messages

ii© EMERSON Motion Control, Inc. 2000Part Number: 400508-02Revision: A2Date: August 2000Printed in United States of AmericaInformation in this documen

Strany 35

28FM-3 Programming Module Installation Manual

Strany 36

29SpecificationsPower consumption: 3W from E Series drive power supply.I/O Supply Voltage: 10-30 VDC.Dimensions and ClearancesFunction Electrical Char

Strany 37

30FM-3 Programming Module Installation Manual2.6(66.0)

Strany 38

31SpecificationsCable DiagramsCustomerSuppliedCableSync.InputSync.InputSync.InputSync.InputSync.OutputSync.OutputM FM FMFSNCE-xxx15', 25' or

Strany 39 - Online Status Indicators

32FM-3 Programming Module Installation ManualSNCE-XXX CableSNCDD-001.5 CableAHBIJDCF38476512BGRD+5MMBAASHIELDGRD+5MMBBAA

Strany 40

33SpecificationsSNCO-003 CableSNCI-003 Cable

Strany 41 - Specifications

34FM-3 Programming Module Installation ManualSNCLI-003 Cable

Strany 42

35SpecificationsCMDX-XXX CableNoteSome CMDX cables may have White/Yellow and Yellow/White wires in place of the White/Orange and Orange/White shown in

Strany 43 - Cable Diagrams

36FM-3 Programming Module Installation ManualCMDO-XXX CableNoteSome CMDO cables may have White/Yellow and Yellow/White wires in place of the White/Ora

Strany 44 - SNCDD-001.5 Cable

37SpecificationsCDRO-XXX Cable89242338371112341614152941926401817313343444127

Strany 45 - SNCI-003 Cable

iiiCustomer ServiceIt is EMERSON Motion Control’s goal to ensure your greatest possible satisfaction with the operation of our products. We are dedica

Strany 46 - SNCLI-003 Cable

38FM-3 Programming Module Installation ManualTIA-XXX CableDDS-XXX Cable

Strany 47 - CMDX-XXX Cable

39SpecificationsTERM-H (Head) TerminatorTERM-T (Tail) Terminator NoteSee the "Multi-drop Communications" section for resistor values.

Strany 48 - CMDO-XXX Cable

40FM-3 Programming Module Installation ManualCMDS-XXX CableCMMS-XXX Cable

Strany 49 - CDRO-XXX Cable

41SpecificationsCFCS-XXX Cable

Strany 50 - DDS-XXX Cable

42FM-3 Programming Module Installation ManualCFCO-XXX Cable

Strany 51 - TERM-T (Tail) Terminator

43SpecificationsCFOS-XXX Cable

Strany 52 - CMMS-XXX Cable

44FM-3 Programming Module Installation ManualVendor Contact InformationSchaffner (AC Line Filters)(800) 367-5566 or (201) 379-7778 www.schaffner.comCo

Strany 53 - CFCS-XXX Cable

45IndexSymbols+/- Limit, 14AAll "On", 14Analog Output, 17BBrake Operation and Wiring, 16CCable Diagrams, 31CDRO-XXX Cable, 37CFCO-XXX Cable,

Strany 54 - CFCO-XXX Cable

46FM-3 Programming Module Installation ManualNNon-volatile Memory Invalid, 12OOver Speed Fault, 14PPower Stage Fault, 13Power-Up Self-Test Failure, 12

Strany 56 - Vendor Contact Information

ivNeed on-site help? EMERSON Motion Control provides service, in most cases, the next day. Just call EMERSON’s customer service center when on-site se

Strany 57

Since 1979, EMERSON Motion Control, a subsidiary of the Emerson Electric Company, has been a leader in the development and manufacturing of motion con

Strany 58

vDocument ConventionsManual conventions have been established to help you learn to use this manual quickly and easily. As much as possible, these conv

Strany 59

viSafety InstructionsGeneral WarningFailure to follow safe installation guidelines can cause death or serious injury. The voltages used in the product

Strany 60

vii Safety ConsiderationsSafety PrecautionsThis product is intended for professional integration into a complete system. If you install the product in

Komentáře k této Příručce