Programming
Subroutine for Jogging the Axis into the Desired Position (Program 1)
‘Allow jogging until either the “Learn” input (ModuleInput.1)
‘or the “Skip” input (ModuleInput.2) goes ON.
Do While ((ModuleInput.1=OFF) AND (ModuleInput.2=OFF))
If (ModuleInput.3=ON) Then ‘Jog+ if the Jog+ input is on
Jog.0.PlusInitiate ‘Vel=0.1in/s
Do While (ModuleInput.3=ON)
If (ModuleInput.5=ON) Then ‘ModuleInput.5 = “Jog Fast”
Jog.0.Vel = 1.0 ‘in/s
Else
Jog.0.Vel = 0.1 ‘in/s
Endif
Loop
Jog.Stop ‘Stop jogging when the Jog+ input goes off.
Endif
If (ModuleInput.4=ON) Then ‘Jog- if the Jog- input is on
Jog.0.MinusInitiate ‘Vel=0.1in/s
Do While (ModuleInput.4=ON)
If (ModuleInput.5=ON) Then ‘ModuleInput.5 = “Jog Fast”
Jog.0.Vel = 1.0 ‘in/s
Else
Jog.0.Vel = 0.1 ‘in/s
Endif
Loop
Jog.Stop ‘Stop jogging when the Jog+ input goes off.
Endif
Loop