20
Rosemount 3051
September 2014
www.rosemount.com
Sensor size
1 Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm) H
2 Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm) H
3 Sensor size 3 — Line sizes greater than 12-in. (300 mm) H
Mounting type
T1 Compression or Threaded Connection H
A1 150# RF ANSI H
A3 300# RF ANSI H
A6 600# RF ANSI H
D1 DN PN16 Flange H
D3 DN PN40 Flange H
D6 DN PN100 Flange H
A9
(2)
900# RF ANSI
AF
(2)
1500# RF ANSI
AT
(2)
2500 # RF ANSI
R1 150# RTJ Flange
R3 300# RTJ Flange
R6 600# RTJ Flange
R9
(2)
900# RTJ Flange
RF
(2)
1500# RTJ Flange
RT
(2)
2500# RTJ Flange
Opposite side support or packing gland
0 No opposite side support or packing gland (required for Pak-Lok and Flange-Lok models) H
Opposite Side Support – Required for Flanged Models
C NPT Threaded Opposite Support Assembly – Extended Tip H
D Welded Opposite Support Assembly – Extended Tip H
Packing Gland – Required for Flo-Tap Models
Packing Gland Material Rod Material Packing Material
J
(3)
Stainless Steel Packing Gland/Cage Nipple Carbon Steel PTFE
K
(3)
Stainless Steel Packing Gland/Cage Nipple Stainless Steel PTFE
L
(3)
Stainless Steel Packing Gland/Cage Nipple Carbon Steel Graphite
N
(3)
Stainless Steel Packing Gland/Cage Nipple Stainless Steel Graphite
R Alloy C-276 Packing Gland/Cage Nipple Stainless Steel Graphite
Isolation valve for Flo-Tap models
0 Not Applicable or Customer Supplied H
1 Gate Valve, Carbon Steel
2 Gate Valve, Stainless Steel
5 Ball Valve, Carbon Steel
6 Ball Valve, Stainless Steel
Temperature measurement
T Integral RTD – not available with Flanged model greater than class 600# H
0 No Temperature Sensor H
R Remote Thermowell and RTD
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.