81
Rosemount 3051
September 2014
www.rosemount.com
Commissioning tag
(1)
A temporary commissioning tag is attached to all transmitters.
The tag indicates the device ID and allows an area for writing the
location.
Optional Rosemount 304, 305 or 306 Integral
Manifolds
Factory assembled to 3051C and 3051T transmitters. Refer to
the following Product Data Sheet (document number
00813-0100-4839 for Rosemount 304 and 00813-0100-4733
for Rosemount 305 and 306) for additional information.
Other seals
Refer to Product Data Sheet 00813-0100-4016 for additional
information.
Output information
Output range points must be the same unit of measure.
Available units of measure include:
Display and interface options
M4 Digital Display with Local Operator Interface (LOI)
• Available for 4-20 mA HART and PROFIBUS PA
M5 Digital Display
• 2-Line, 5-Digit LCD display for low power output
• 2-Line, 8-Digit LCD display for 4-20 mA HART, F
OUNDATION
fieldbus and PROFIBUS PA
• 3-Line, 7-Digit LCD display for Wireless
• Direct reading of digital data for higher accuracy
• Displays user-defined flow, level, volume, or pressure units
• Displays diagnostic messages for local troubleshooting
• 90-degree rotation capability for easy viewing
Configuration buttons
Rosemount 3051 will ship with no buttons unless option D4
(Analog Zero and Span), DZ (Digital Zero), or M4 (LOI) for local
configuration buttons are specified.
The Rosemount 3051 Wireless Transmitter is available with a
Digital Zero button installed with or without the LCD display
digital display.
Transient protection (option code T1)
Tested in accordance with IEEE C62.41.2-2002, Location
Category B
6 kV crest (0.5 s - 100 kHz)
3 kA crest (8 × 20 s)
6 kV crest (1.2 × 50 s)
Bolts for flanges and adapters
Options permit bolts for flanges and adapters to be obtained
in various materials
Standard material is plated carbon steel per ASTM A449, Type
1
L4 Austenitic 316 Stainless Steel Bolts
L5 ASTM A 193, Grade B7M Bolts
L6 Alloy K-500 Bolts
Conduit plug
DO 316 SST Conduit Plug
Single 316 SST conduit plug replaces carbon steel plug
Rosemount 3051C Coplanar Flange and 3051T
Bracket Option
B4 Bracket for 2-in. Pipe or Panel Mounting
• For use with the standard coplanar flange configuration
• Bracket for mounting of transmitter on 2-in. pipe or panel
• Stainless steel construction with stainless steel bolts
(1) Only applicable to FOUNDATION fieldbus.
Pressure
atm inH
2
O@4 °C
(2)
g/cm
2
psi
mbar mmH
2
O kg/cm
2
torr
bar mmHg Pa
cmH
2
O
@4 °C
(1)(2)
(1) Field configurable only, not available for factory calibration or custom
configuration (option code C1 “Software configuration”).
inH
2
0
mmH
2
O
@4 °C
(2)
kPa
mH
2
O
@4 °C
(1)(2)
inHg ftH
2
0 MPa
(2)
(2) Not available with Low Power (output option code M) or PROFIBUS PA
(output option code W).
ftH
2
O
@60 °F
(1)(2)
hPa
(1)(2)
inH
2
O@60 °F
(2)
kg/m
2(1)(2)
cmHg
@0 °C
(1)(2)
mHg
@0 °C
(1)(2)
psf
(1)(2)
ftH
2
O
@4 °C
(1)(2)