5.1.3 Coil Inspection and Replacement (2D / 3D)
Refer to figure 5.1 for the location of the injection coil.
The coil may be removed by unplugging the harness
from the coil and lifting the coil. The retention snap on
the top of the coil is held in place by an internal spring
and will snap off with sufficient lifting force. Do not
lose the retention snap!
The resistance of a good coil should be 490 Ohms to
600 Ohms.
A coil that is “shorted” or “open” may have blown the
1/2 amp accessory fuse on the side of the module.
Inspect the fuse when replacing the coil or
troubleshooting a “failure to inject”. Refer to figure
5.5. Replace the retention snap when the coil is
installed.
Figure 5.5 Accessory Fuse Location
5.1.4 Coil Inspection and Replacement (4D)
The terminal box cover and side shroud must be
removed to inspect or replace the injection coil of a
4D compressor.
Remove (3) terminal box and (4) head cover screws.
To replace the coil, loosen the conduit clamp as
shown in the photo below. Remove the coil from the
mounting bracket and install a new coil.
Inspect the 1/2 amp accessory fuse on the side of the
module and replace if necessary. Use a fast-blow
replacement fuse such as Bussman AGC - 1/2 A.
Install the harness shroud before installing the
terminal box cover.
Loosen
Conduit Clamp
to Change Coils
Remove
Head Cover
Screws
1
/2 Amp
Accessory
Fuse Here
Remove
Terminal
Box Cover
AE8-1337 R1