May 2015
26
Quick Start Guide
2. The terminal pins of the Model 3051S SuperModule must be provided with a
degree of protection of at least IP20 in accordance with IEC/EN 60529.
3. The Model 3051S enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should be taken to protect
it from impact or abrasion if located in a zone 0 area.
IG IECEx Intrinsic Safety – Group I - Mining (IG with Special A0259)
Certificate: IECEx TSA 14.0019X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: FISCO FIELD DEVICE Ex ia I Ma (-60 °C
≤ T
a
≤ +70 °C)
Special Conditions for Safe Use (X):
1. If the apparatus is fitted with optional 90 V transient suppressor, it is not
capable of withstanding the 500 V insulation test required by Clause 6.3.13 of
IEC60079-11:2011. This must be taken into account when installing the
apparatus.
2. It is a condition of safe use that the above input parameters shall be taken into
account during installation.
3. It is a condition of manufacture that only the apparatus fitted with housing,
covers and sensor module housing made out of stainless steel are used in
Group I applications.
N7 IECEx Type n
Certificate: IECEx BAS 04.0018X
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T5 Gc, (-40 °C
≤ T
a
≤ +85 °C)
Special Condition for Safe Use (X):
1. The equipment is not capable of withstanding the 500 V insulation test
required by clause 6.5 of EN 60079-15:2010. This must be taken into account
when installing the equipment.
Brazil
E2 INMETRO Flameproof
Certificate: CEPEL 03.0140X [Mfg USA, Singapore, Germany],
CEPEL 07.1413X [Mfg Brazil]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-1:2009,
ABNT NBR IEC 60529:2009
Markings: Ex d IIC T* Ga/Gb, T6(-40 °C
≤ T
a
≤ +65 °C), T5(-40 °C ≤ T
a
≤ +80 °C),
IP66*
FISCO
Voltage U
i
17.5 V
Current I
i
380 mA
Power P
i
5.32 W
Capacitance C
i
0
Inductance L
i
0
4801_QIG_RevMA.fm Page 26 Wednesday, May 6, 2015 1:15 PM