11
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
MultiVariable Flow performance
(1)
Mass, Energy, Actual Volumetric, and Totalized Flow Reference Accuracy
(2)
Long term stability
Warranty
(1)
Models
(1)(2)
(1) Applies to the 3051SMV_M MultiVariable Type only. Flow performance specifications assume device is configured for full compensation of static pressure,
process temperature, density, viscosity, gas expansion, discharge coefficient, and thermal correction variances over a specified operating range.
(2) Uncalibrated differential producer (0.2 < beta < 0.6 Orifice) installed per ASME MFC 3M or ISO 5167-1. Uncertainties for discharge coefficient, producer bore,
tube diameter, and gas expansion factor as defined in ASME MFC 3M or ISO 5167-1. Reference accuracy does not include RTD sensor accuracy.
Ultra for Flow Classic MV
3051SMV DP Ranges
2-3
±0.65% of Flow Rate over a 14:1 flow range
(200:1 DP range)
±0.70% of Flow Rate over 8:1 flow range
(64:1 DP range)
DP Range 1 N/A ±0.90% of Flow Rate over 8:1 flow range
(64:1 DP range)
Models Ultra and Ultra for Flow
(1)
(1) Ultra is only available for 3051SMV_ _3, 4. Ultra for Flow is only available for 3051SMV DP Ranges 2-3.
Classic and Classic MV
3051SMV DP Ranges 2-5
AP & GP Ranges
3-4
±0.20% of URL for 10 years; for ±50 °F (28
°C) temperature changes, up to 1000 psi
(68,9 bar) line pressure
±0.125% of URL for 5 years; for ±50 °F
(28 °C) temperature changes, up to
1000 psi (68,9 bar) line pressure
Process Temperature
RTD Interface
(2)
(2) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples
of compatible RTDs include Rosemount Series 68 and 78 RTD Temperature Sensors.
The greater of ±0.185°F (0.103 °C) or 0.1% of reading per year (excludes RTD sensor
stability).
Models
(1)
(1) Warranty details can be found in Emerson Process Management Terms & Conditions of Sale, Document 63445, Rev G
(10/06).
Ultra and Ultra for Flow Classic and Classic MV
3051S Scalable Products 12-year limited warranty
(2)
(2) Rosemount Ultra and Ultra for Flow transmitters have a limited warranty of twelve (12) years from date of shipment. All other
provisions of Emerson Process Management standard limited warranty remain the same.
1-year limited warranty
(3)
(3) Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of
shipment by seller, whichever period expires first.