Reference Manual
00809-0200-4801, Rev CA
July 2010
Rosemount 3051S
A-8
SENSOR_CAL_
LOC
24 NULL N/A The location of the last sensor calibration. This describes the
physical location at which the calibration was performed.
SENSOR_CAL_
DATE
25 0 N/A The date of the last sensor calibration. This is intended to
reflect the calibration of that part of the sensor that is usually
wetted by the process.
SENSOR_CAL_
WHO
26 N/A The name of the person responsible for the last sensor
calibration.
SENSOR_
ISOLATOR_MTL
27 E Read
Only
Defines the construction material for the isolating diaphragms.
SENSOR_FILL_
FLUID
28 E Read
Only
Defines the type of fill fluid used in the sensor.
SECONDARY_
VALUE
29 SVU Read
Only
The secondary value, related to the sensor.
SECONDARY_
VALUE_
UNIT
30 See Table 19
and footnote4
E The engineering units to be used with the
SECONDARY_VALUE.
TB_DETAILED_
STATUS
31 N/A Read
Only
Indicates the state of the transmitter. The parameter contains
specific codes relating to the transducer block and the
pressure sensor specifically.
FACTORY_CAL_
RECALL
32 1: No Recall
2: Recall
3: Save
factory trim
1 E Recalls the sensor calibration set at the factory.
If the device is in “factory mode”, a value of 3 may be entered
to save the current trim values into a factory area of NV
memory to be used for factory calibration recall
MODULE_TYPE 33 252: Unknown E Read
Only
Indicates the type of sensor module.
SENSOR_CAL_
TYPE
34 See Table 39 252: Unknown E The type of last sensor calibration.
FLANGE_TYPE 35 See Table 50 0 N/A Indicates the type of flange that is attached to the device. See
Flange Type Codes.
FLANGE_MTL 36 See Table 49 0 N/A Indicates the type of material that the flange is made of. See
Flange Material Codes.
REM_SEAL_
NUM
37 See Table 45 0 N/A Indicates the number of remote seals that are attached to the
device. See Remote Seal Number Codes.
REM_SEAL_
TYPE
38 See Table 46 0 N/A Indicates the type of remote seals that are attached to the
device. See Remote Seal Type Codes.
REM_SEAL_ISO
_MTL
39 See Table 44 0 N/A Indicates the type of material that the remote seal isolators are
made of. See Remote Seal Isolator Material Codes.
REM_SEAL_FILL 40 See Table 43 0 N/A Indicates the type of fill fluid used in the remote seals. See
Remote Seal Fill Fluid Codes.
O_RING_MTL 41 See Table 48 0 N/A Indicates the type of material that the flange o-rings are made
of. See O-ring Material Codes.
DRAIN_VENT_
MTL
42 See Table 47 0 N/A Indicates the type of material that the drain vents on the flange
are made of. See Drain Vent Material Codes.
PRIMARY_
VALUE_
DAMPING
43 0.0f 0.0 Sec. Time constant of a single exponential filter for the PV, in
seconds.
Parameter Index Valid Range Initial Value Units Other Description